Ruijie RG-EG210G-E Series Routers Hardware Installation and Reference Guide 

Installing the Router 

 

 

Do not use bare wire. 

 

The grounding electric resistance should be less than 

1Ω. 

 

To guarantee the security of the body and the device, the router must be well-grounded. The grounding resistance 

for combined grounding should be less than 1Ω. 

 

The maintenance personnel shall check whether or not the AC socket powering the router is well connected to the 

building protective earth (PE). If not, the personnel shall connect the grounding lug of the AC socket with the PE by using 

a grounding connector. 

 

The AC socket shall be installed near the equipment and shall be easily used. 

 

When installing the router, make sure the grounding is connected first and disconnected last. 

 

The cross-sectional area of PE conductor shall be at least 2.5 mm

2

 (12AWG). 

3.5  Installing Power Cables 

RG- EG210G-E series router uses 3-conductor power cables. You are suggested to use a single-phase 3-conductor outlet 

or  a  multifunction  microcomputer  outlet  with  neutral connector.  The  neutral point  of  the  power  supply  shall  be  securely 

grounded in the building. In most buildings, the neutral point of a power supply has been grounded during the construction. 

You need to make sure the power supply is properly grounded. 

Please take the following steps: 

 

Plug one end of the power cable into the power socket on the backpanel of the router, and plug the other end into the 

AC power supply outlet. 

 

Check whether the power LED on the front panel of the router lights up or not. The LED indicator will light up if the 

power supply is properly connected. 

3.6  Connecting the External Port Cables 

Step 1: Connect one end of the RJ45 connector to the Ethernet interface of the device board, and the other end to the 

NMS or a control terminal. 

Step 2: Insert the twisted pair with the RJ45 port into the appropriate interface according to the identification on the panel 

of the module. Distinguish the crossover cable and straight-through cable. 

3.7  Installation Verification 

Verifying the Cabinet 

 

Verify if the external power supply matches the distribution panel of the cabinet. 

 

After equipment is installed, verify if the front/back cabinet doors can be closed. 

 

Verify that the cabinet has been fastened completely, and does not move or tilt. 

 

Verify that the equipment has been installed in the cabinet, and all the cables have been fastened to the cabinet. 

Verifying the Cables 

Summary of Contents for RG-EG210G-E Series

Page 1: ...Ruijie RG EG210G E Series Routers Hardware Installation and Reference Guide...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ite https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Suppo...

Page 4: ...tor familiar with mainstream router configuration commands can use this device without training 1 1 RG EG210G E Specifications Model RG EG210G E CPU Dual core CPU with the clock speed of 1 35GHz Flash...

Page 5: ...ference in which case the user may be required to take adequate measures Appearance Figure 1 1 Appearance of RG EG210G E Figure 1 2 Front Panel of RG EG210G E Note 1 System status LED 2 Reset button 3...

Page 6: ...ce in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to clean the device once every 3 mont...

Page 7: ...supply and damp wet ground or floor Before installing the device find out the location of the emergency power supply switch in the room First cut off the power supply in the case of an accident Try to...

Page 8: ...urrent is 30 mA When twice of the total leakage current of the system is greater than 30 mA the system must be equipped with two or more leakage protectors For the leakage current value of each power...

Page 9: ...E Series Router Temperature Relative Humidity 0 C to 40 C 32 F to 104 F 10 to 90 40 F to 158 F The requirements for the sampling site of the temperature and humidity in the operating environment of t...

Page 10: ...unding required for EMC design includes shielding ground filter ground noise and interference suppression and level reference All the above constitute the comprehensive grounding requirements The resi...

Page 11: ...of the electrical equipment and anti lightning grounding device Keep the equipment away from high power radio transmitter radar transmitting station and high frequency large current device Measures m...

Page 12: ...g points Whether ventilation requirements are met for the device Whether the requirements of temperature and humidity are met for the device Whether power cables are already laid out and whether the r...

Page 13: ...le management bracket and cables Install the tray and wiring layer on the cabinet according to the configuration of one cabinet with one device installed or one cabinet with multiple devices installed...

Page 14: ...he building In most buildings the neutral point of a power supply has been grounded during the construction You need to make sure the power supply is properly grounded Please take the following steps...

Page 15: ...uijie RG EG210G E Series Routers Hardware Installation and Reference Guide Installing the Router Verify that the fibers and twisted pairs match the ports Verify that the cables have been bound properl...

Page 16: ...onnect to the SSID for configuration Figure 4 1 Schematic Diagram of the Configuration Environment 4 2 Startup Check 4 2 1 Checking before the Device is Powered on The router is fully grounded The pow...

Page 17: ...ters Hardware Installation and Reference Guide System Debugging 4 3 Configuring Router To use the router more configuration should be made on the device Please refer to the corresponding command refer...

Page 18: ...set Button for more than 5 seconds to restore the default password The status indicator is not on after the device is started The power supply module does not supply power Check whether the power sock...

Page 19: ...all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 10...

Page 20: ...or the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4...

Page 21: ...seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend or suffer remova...

Page 22: ...rack and cabling slot inside and outside the cabinet should be smooth without sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining P...

Page 23: ...running or cause device damage or cable damage during commissioning The power cords cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding...

Page 24: ...bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table B 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300...

Reviews: