Although much has been done in RG-WALL1600-S3600 to prevent static electricity, great damage may be caused to the
circuitry and equipment when the static electricity exceeds a certain limit. In the communication network of the
RG-WALL1600-S3600, electrostatic induction may come from the following sources: External electric field produced by
the high-voltage supply cable, lightning, etc; Internal systems such as the indoor floor and the entire structure.
To prevent damage from static electricity, you must pay attention to the following:
Properly ground the equipment.
Take dust prevention measures in the room.
Maintain an appropriate humidity.
Always wear an anti-static wrist strap when you touch any circuit board.
Try to hold a circuit board by its edges. Do not touch any components or the PCB.
Use an anti-static shielding bag to properly store the board.
Do not let any clothes touch a circuit board. An antistatic wrist strap can only prevent human static electricity from
damaging the circuit board, but cannot prevent any static electricity on clothes.
For safety, use a multimeter to measure the resistance between yourself and the ground, which should be
within the range from 1
Ω to 10 Ω.
Make sure that the device is properly grounded when the anti-static wrist strap is connected to the ground
through the chassis jack.
Installation Site Requirements
RG-WALL1600-S3600 must be used in the room. This series of products are desktop devices, so they can be placed in
non-machine-room or mounted into a rack with the support of a tray. To ensure normal operation and a prolonged use life
of the equipment, the installation site must meet the following requirements.
Non-machine-room Installation Requirements
Please ensure that the rack meets the following requirements before installing the RG-WALL1600-S3600 in
non-machine-room.
Install the device in open space if possible. If it is installed in closed space, please make sure that there is a good
ventilation system.
Ensure that the supporting body is firm enough to support the device and its accessories.
For ventilation, ensure that there is enough space left between the supporting body and the front panel as well as the
supporting body and the back panel.
Place the device far from an office desk. Because ventilators are on the top of the chassis, avoid damages to the
device caused by dust retention or water sprays.
Rack Mounting Requirements
To mount the RG-WALL1600-S3600 in a cabinet, verify that the cabinet meets the following conditions:
Install the device in an open cabinet as much as possible. If you install the device inside a closed cabinet, be sure
that the cabinet has a good ventilation and heat dissipation system.
Be sure that the cabinet is firm enough to bear the weight of the RG-WALL1600-S3600 and its installation
accessories.
Be sure that the dimensions of the cabinet is appropriate for installation of the RG-WALL1600-S3600 that can
reserve a certain space for the front, back, left and right panels for heat dissipation.
The cabinet should be properly grounded.
Ventilation Requirements