Indicator
Definition
Status
Meaning
connected to the AC terminal.
Solid green
The power supply is working normally.
Solid yellow
It indicates:
A. The working environment temperature of the
power supply exceeds the normal
temperature range.
B. The power supply is not matched correctly.
Solid red
Power supply fault (any fault).
Off It
indicates:
A. The power supply is not in position.
B. The power supply is in position but not
connected to the AC terminal.
Solid green
The power supply is working normally.
Solid yellow
It indicates:
A. The working environment temperature of the
power supply exceeds the normal
temperature range.
B. The power supply is not matched correctly.
PWR2
Indicates the power
module status.
Solid red
Power supply fault (any fault).
Solid green
Gigabit Link.
Blinking green
Gigabit ACT.
Solid yellow
10/100M Link
MGMT
Indicates the external
management port
Blinking yellow
10/100M ACT
Solid
green
The fans are in position and are working
normally.
Solid yellow
It indicates:
A. One fan is not in position or in the
powered-off status.
FAN
Indicates the fan
status.
Solid red
It indicates:
A. Any fan in the system is faulty.
B. Two or more than two fans are not in
position or in the powered-off status.
C. The fan type is configured incorrectly
Solid green
It indicates:
A. Port link is up.
B. Data is transmitted on the port.
Link/ACT indicator
Indicates the port
status.
Off
Port link is not up.
1.5 Module Types Supported by the RG-S6200Series Switches
The RG-S6200 series switch supports the following modules:
1.
M6200-16XS extension module, which is used to support the extension for the RG-6200 series switch.
Summary of Contents for RG-S6200 Series
Page 1: ...Installation Manual RG S6200 Series Switch...
Page 21: ...The RG S6200 series are not provided with a tool kit Please prepare tools on your own...
Page 24: ......
Page 25: ......
Page 26: ......
Page 41: ......