Do not place the device in a damp/wet location. Do not let any liquid enter the chassis
Keep the AP far away from the grounding or lightning protection devices of power equipment.
Keep the AP away from radio stations, radar stations, high-frequency high-current devices, and microwave ovens.
Any nonstandard and inaccurate electrical operation can cause an accident such as fire or electric shock,
thus causing severe even fatal damages to human bodies and device.
Direct or indirect touch through a wet object on high voltage and power line can bring a fatal danger.
Preparing Installation Site
The AP must be installed indoors. To ensure its normal operation, the installation site must meet the following
requirements.
Installation
Install the AP in a well-ventilated environment. If it is installed in a closed room, make sure there is a good cooling
system.
Make sure the site is sturdy enough to support the AP and its accessories.
Make sure the site has enough space for installing the AP and leave sufficient room around the AP for ventilation.
Ventilation
For proper ventilation, leave sufficient space around the AP.
Temperature and Humidity
To ensure normal operation and service life of the device, maintain appropriate temperature and humidity levels in your
equipment room. See Table 2-1 . Improper room temperature and humidity can cause damages to the device.
High relative humidity may affect
insulation materials, resulting in poor insulation and even electrical leakage, and
sometimes may lead to change of mechanical properties of materials and corrosion of metal parts.
Low relative humidity may dry and shrink insulation sheets and cause static electricity that can damage the circuitry
inside the device.
High temperature greatly reduces reliability of the device and shortens its service life.
Table 2-1 Required Temperature and Humidity for the RG-AP320-I
Temperature
Relative Humidity
-10
º
C to 55
º
C
5% to 95%