Tumbler MPR 300
18
5.2
Regular maintenance
Regular maintenance of the machine must be carried out every 2000
hours of operation but at least once per year.
Maintenance schedule:
a)
Inspect the safety devices as described in Chapter 1.1 Safety
instructions!
b)
Carry out a test run with open machine (caution: moving
parts)!
c)
Check the air filter and air oil separator of the vacuum pump
and replace, if necessary!
d)
Change the oil in the vacuum pump!
e)
Check the cooling performance of the cooling unit; service, if
necessary, and clean condenser!
f)
Check the function of pressure transmitters and temperature
sensors!
g)
Inspect the hoses (vacuum system)!
h)
Check the radial shaft seals for tightness; replace otherwise!
i)
Read out the error memory (frequency converter)!
5.3
Repairs and spare parts
As a damaged part on a machine is usually damaged due to causes
unrelated to the part, always carry out a fault diagnosis.
Contact our Service Hotline at +49 7748-523-11 for spare parts or
malfunctions. Please keep the machine type and number to hand.
6
Disposal
All materials and operating fuels must be separated and
disposed of in accordance with nationally applicable regu-
lations!