Cutting Centre SR 2 Turbo
9
2.3
Connecting the machine
The machine is connected to a three-phase current outlet; its data
(voltage, amperage) must agree with the specifications on the type
plate of the machine.
The machine must be decommissioned until a damaged
power supply line has been repaired!
The power supply line must be regularly checked!
Check the correct rotational direction of the machine by
starting it. A message appears on the display in case of in-
correct rotating field!
In such a case, an electrician must change the direc-
tion of rotation inside the mains plug.
The power supply to the machine must be fuse-pro-
tected with 16A secured with an AC/DC sensitive
ground-fault circuit interrupter (type B).
3
Operating instructions
Please refer to the short instructions supplied with your machine for
the operation of your cutting centre.
Follow also the safety instructions in Chapter 1.1!
In its respective life cycle phases (transport, commission-
ing, setup, operation, cleaning, decommissioning, care /
maintenance, dismantling / disposal) this machine is de-
signed for 1-person operation!
When using this machine, no other person may be present
near the machine. The exception (2-man operation):
Transport of machine and machine parts
Commissioning
Maintenance activities