Technical
Specifications
3.2 Environmental Specifications
Parameter
Range
Comments
Ambient Operating
Temperature
-20 to 60
°
C
-40 to 85
°
C (Optional)
Ambient Temperature as measured from
a 30 cm radius surrounding the center of
the enclosure.
Ambient Storage
Temperature
-40 to 85
°
C
Ambient Relative
Humidity
up to 95%
Non-condensing, 55
°
C, 6 cycles
Vibration 1g
(10-500Hz)
Shock 30g
11ms
Table 9: Environmental Specifications
3.3 Power Supply Specifications
Power Supply
Type
Minimum
Input
Maximum
Input
Fuse
Rating
Maximum
Power
Consumption
24 VDC
9 VDC
36 VDC
3A (T)
9W
Table 10: Power Supply Specifications
NOTES:
•
(T) denotes a time-delay fuse
•
For continued protection against risk of fire, replace only with same type and
rating of fuse.
3.4 Failsafe Relay Specifications
Parameter
Value
Max Switching Voltage
30VAC, 80VDC
Rated Switching Current
0.3A @ 30VAC
1A @ 30VDC, 0.3A @ 80VDC
Table 11: Failsafe Relay Specification
NOTES:
•
Resistive
Load.
•
For Class-2 circuits only.
Isolation
Comments
1500 V
rms
Dielectric test voltage (1 minute) between coil & contacts
Table 12: Failsafe Relay Isolation
RuggedCom® 18
RuggedSwitch™
i
800 family