Page 1: ...RuggedSwitch i800 Family Installation Guide www ruggedcom com...

Page 2: ...e of this material The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions We appreciate any suggested improvements We reserv...

Page 3: ...e interference at his expense Caution This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those spe...

Page 4: ...Signal Description 15 2 6 Memory Slot 16 3 Technical Specifications 17 3 1 Type Test Specifications 17 3 2 Environmental Specifications 18 3 3 Power Supply Specifications 18 3 4 Failsafe Relay Specif...

Page 5: ...00 family s specifications this product is not intended for mission critical power substation applications For equipment designed for these environments please visit http www ruggedcom com or contact...

Page 6: ...ptions available in several models outlined in Section 1 3 2 below Fail Safe Relay Power LEDs Power Connector RS 232 Console Port Ports 1 4 6 8 10 100 BaseTx Memory Slot Ports 5 7 7 8 or 9 10 100 1000...

Page 7: ...and the bottom LED is always the Link Activity indicator 1 3 2 Front Panel Ethernet Options A varied mix of Ethernet port options is available across four basic models The basic configuration and ava...

Page 8: ...on connecting the power supplies and Ground see Section 2 2 For details on connecting the Fail Safe Relay see Section 2 3 Ratings 12 24V 2A P1 P1 GND P2 P2 Fail Safe Relay Power Connector back front...

Page 9: ...X 1000SX LX 10 100Base Tx Figure 3 Bottom Panel For details on connecting the console port see Section 2 4 For a description of the memory slot see Section 2 6 RS 232 Console Port Micro SD Memory Slot...

Page 10: ...omes with a standard DIN rail mounting bracket Figure 4 details the mounting configuration for a standard 1 DIN Rail DIN Rail Power 2 i802 Figure 4 DIN Rail Mounting Power 1 R 3 1 4 2 5 6 7 8 Alarm Re...

Page 11: ...power supplies A list of power and ground connections follows in Table 3 Pin Function Connector P1 DC Power Supply 1 positive terminal Phoenix connector P1 DC Power Supply 1 negative terminal Phoenix...

Page 12: ...e polarity markings on the unit Chassis Ground must be connected to the protective earth The internal connection between P1 P2 and GND means that if two power supplies are connected to the unit their...

Page 13: ...or power loss occurs A common application for this output is to signal an alarm in the event of power failure back front Figure 7 Failsafe Output Relay Pin Function Normally Closed Normally closed no...

Page 14: ...B9 Female RJ45 Male DCD Carrier detect 1 2 RxD Receive data to DTE 2 5 TxD Transmit data from DTE 3 6 DTR Data terminal ready 4 3 Signal GND 5 4 DSR Data set ready 6 1 RTS Ready to send 7 8 CTS Clear...

Page 15: ...ted Case Shield Chassis Ground Table 6 RJ45 Ethernet port pin out NOTE The unused pins 4 5 7 and 8 are terminated to Chassis Ground via a network that improves EMI and ESD performance RuggedCom does n...

Page 16: ...the memory card to extremes of temperature or humidity Do not expose the memory card to large magnetic or static electric fields Do not bend or drop the card Before applying power to a replacement un...

Page 17: ...tic Field Enclosure ports 30 A m 50 60 Hz IEC 61000 4 11 Voltage Dips DC Power ports 30 reduction for 0 5 period Signal ports IEC 61000 4 12 Damped Oscillatory DC Power ports 1kV common mode 0 5kV dif...

Page 18: ...Supply Type Minimum Input Maximum Input Fuse Rating Maximum Power Consumption 24 VDC 9 VDC 36 VDC 3A T 9W Table 10 Power Supply Specifications NOTES T denotes a time delay fuse For continued protecti...

Page 19: ...cations Order Code Tx min dBm Tx max dBm Rx Sensitivity dBm Rx Saturation dBm Typical Distance km Power Budget dB _FG01 9 5 4 0 20 0 0 0 4 10 5 _FG03 9 5 3 0 21 3 0 10 11 5 _FX11 19 14 32 14 2 13 _FX0...

Page 20: ...46 0 833 3 833 4 421 3 1 4 2 5 6 7 8 Alarm R 3 490 3 918 NOTE All dimensions are in inches Figure 10 Mechanical Specifications Parameter Value Comments Dimensions 4 625 x 2 25 x 3 75 inches 117 x 57 x...