3.3 Fiber Optical Port Specifications
Speed
Standard
Mode /
Connector
Tx
λ
λ
λ
λ
(nm)
Cable
Type
2
(
µ
µ
µ
µ
m)
Tx Pwr
(dBm peak)
3
(Min / Max)
Rx
Sensitivity
(dBm Average)
3
Rx Saturation
(dBm Peak)
3
Typical
Distance
(km)
1
Power
Budget
(dB)
100BaseFX
MM / ST
1310
50/125
-15.7
-33.5
-11
2
17
100BaseFX
MM / SC
1310
50/125
-16/-11
-33
-11
2
17
100BaseFX
MM / LC
1310
50/125
-19 / -14
-32
-14
2
15
100BaseFX
MM / MTRJ
1310
50/125
-16/-11
-33.5
-11
2
17
100BaseFX
SM / SC
1310
9/125
-13/5
-31
-4
20
20
100BaseFX
SM / LC
1310
9/125
-15/-8
-31
-5
15
16.5
Notes:
1.
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2.
To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3
dBm.
3.4 Networking Standards Supported
Parameter
10FL
Module
100FX
Module
Notes
IEEE 802.3
10BaseT
IEEE 802.3u
100BaseTX / 100BaseFX
IEEE 802.3x
FDX, Flow Control