background image

SPECIFICATION

PRODUCT

   

SAFETY MODEL NO.   

DC VOLTAGE

Note.2

RATED CURRENT

CURRENT RANGE

RATED POWER (max.) 

RIPPLE & NOISE (max.) 

Note.3

OUTPUT

SETUP, RISE TIME          

Note.6

HOLD UP TIME (Typ.)               

VOLTAGE RANGE           

Note.7

FREQUENCY RANGE

EFFICIENCY (Typ.)

AC CURRENT (Typ.)

INPUT

ENVIRONMENT

INRUSH CURRENT (Typ.)

LEAKAGE CURRENT(max.)

SAFETY STANDARDS

SAFETY &

EMC
(Note. 8)

WORKING TEMP.

WORKING HUMIDITY

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

MTBF

DIMENSION

OTHERS

PACKING

PROTECTION

VOLTAGE TOLERANCE 

Note.4

LINE REGULATION         

Note.5

LOAD REGULATION       

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

CONNECTOR

PLUG

CABLE

OVERLOAD

OVER VOLTAGE

OVER TEMPERATURE

EMC IMMUNITY

EMC EMISSION

12V

100mVp-p

5A

60W

0 ~ 5A

GSM60B12-P1J

GSM60B12























For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

      (as available on http://www.meanwell.com)

80 ~ 264VAC     120 ~ 370VDC

47 ~ 63Hz

88%

50ms / 230VAC          15ms / 115VAC  at full load

1000ms, 30ms / 230VAC          1500ms, 30ms / 115VAC  at full load

±

3.0%

±

1.0%

±

3.0%

1.4A / 115VAC          1A / 230VAC

 30A / 115VAC          65A / 230VAC

-30 ~ +60

 (Refer to "Derating Curve")

20% ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

±

0.03%  / 

 (0 ~ 40

)

105 ~ 160%  rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

Protection type : Shut down o/p voltage, re-power on to recover

Shut down o/p voltage, re-power on to recover

12.6 ~ 16.2V

Touch current < 50   A/264VAC

I/P-O/P:4KVAC   

I/P-O/P:100M Ohms / 500VDC / 25

/ 70% RH

720K hrs min.  MIL-HDBK-217F(25

)

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

125*50*31.5mm (L*W*H)

0.32Kg; 40pcs/13.8Kg/1.05CUFT

See page 3  ; Other type available by customer requested

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A

ANSI/AAMI ES60601-1 / ES60601-1-11, TUV EN60601-1 / 60601-1-11 approved

ISOLATION LEVEL

Primary-Secondary: 2xMOPP

Power Supply Specification

See page 3  ; Other type available by customer requested

Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B

,CAN ICES-3(B)/NMB-3(B)

Summary of Contents for DodgeAttack

Page 1: ...tallation Manual For models from December 2017 onwards Rugged Interactive Unit 1 Callywith Court Callywith Industrial Estate Bodmin Cornwall UK PL231 2RQ 44 0 1726 981 123 www rugged interactive co uk...

Page 2: ...and Installation Checklist 1 3 Product Overview 1 4 Ordering and Installation Timeline 1 5 Getting Started 1 6 Place Order Section 2 Safety Guidelines 2 1 Installation Safety Guidelines 2 2 In Play S...

Page 3: ...provide guidance only the installation of the Rugged Interactive product will be under your control You will be responsible for making sure upon completion of the installation it is safe to use As al...

Page 4: ...uired for export customers Complete site survey Send purchase order or confirm order Make first payment Discuss graphic requirements and provide logos and branding guidelines Approve graphics Make sec...

Page 5: ...ach successful hit accuracy and agility are key Brightly lit targets which flash when a hit is registered along with fun sounds and a large scoreboard it is Dodgeball like never before DodgeAttack con...

Page 6: ...and CAD files can be supplied upon request Existing Parks When retrofitting existing parks all specifications can be found within this manual or CAD files are available at request If further informat...

Page 7: ...its weight and gameplay If possible avoid stud walls or unsupported portal infills If in doubt always contact a suitably qualified surveyor to check Visually check the product for any signs of damage...

Page 8: ...mber of staff immediately Ensure you familiarise yourself with any additional facility rules that may apply Ensure that the play area in front of the equipment is clear before attempting to participat...

Page 9: ...leather soles high heels sandals boots or bare feet No food drink or chewing gum during participation No phones or cameras in the activity area Do not leave clothing or personal belongings around the...

Page 10: ...d Interactive immediately if anything is missing 2 x Targets 1 x Hub control box 4 x Control box mounting brackets including 12 x M5 x 12mm screws 2 x 30m target connection cables 1 x Start button inc...

Page 11: ...Tools and Components List Arrange the necessary tools and the team to install the product Ladder Spirit level Socket Set Industrial vacuum cleaner Dustpan and brush SDS impact drill Cordless drill wit...

Page 12: ...the following pages Please read through ALL of this prior to beginning the installation and if you are in any doubt contact Rugged Interactive If you have any concerns on how or what the product is i...

Page 13: ...te strain relief for connection points To prevent electric shock keep all electric components away from contact with water IMPORTANT Take anti static precautions Structure Mount onto timber or steel f...

Page 14: ...elative bounciness of trampolines when determining the installation height Layout of DodgeAttack is at the discretion of the installer park constructor Operating Environment Keep out of direct sunligh...

Page 15: ...face material The HUB can be recessed to be flush with the surface or affixed on top of the foam backed vinyl if necessary A central position is recommended for easy comparison of scores Note Cables e...

Page 16: ...c t i o n p a ne l a f f i x e d o ntot h esu r f a c em a te r i a l w a ll p o le e tc A p o si t i o nne x tt ot h ee nt r a nc eo f t h eDo d g e At t a c k a r e na i s r e c o mme nd e df o r e...

Page 17: ...metal using suitable screws or bolts M12 bolts with nuts and washers supplied Figure 3 4 1 shows a typical DodgeAttack target installation Figure 3 4 1 Typical DodgeAttack Target Installation DodgeAt...

Page 18: ...DodgeAttack Order and Installation Manual Installation DodgeAttack Section 3 Installation Rugged Interactive 2021 Figure 3 4 2 Installing a DodgeAttack Target...

Page 19: ...ice when running data cables to and from products targets and boxes Support long cables at least every 50 cm and provide adequate strain relief for connection points Team 1 Team 2 Score Box HUB Back V...

Page 20: ...k Section 3 Installation Rugged Interactive 2021 Score Box HUB CAT5 Cable Connections Notes Cables come out the back of each unit Cables need to be installed as shown in Figure3 4 3 Team 1 Start Butto...

Page 21: ...Each target has its own sensor so each one should be checked To adjust the sensitivity locate the silver plate on the reverse of the targets as mentioned in section 3 4 this should have remained clear...

Page 22: ...rgets by throwing game balls One 1 point is earned for any target hit The game balls are split into 2 even groups on the centreline The centre line is the off sides line You are not allowed to cross t...

Page 23: ...udes hand eye coordination teamwork building quick reflexes learning to catch and throw the ball while building a competitive spirit Gameplay Upon pressing the start button all targets illuminate and...

Page 24: ...cs 3 years on all other parts Regulatory Requirements CE Approved Operating Environment Indoors keep dry and out of direct sunlight Mount to a framework or structure of a suitable construction Optimum...

Page 25: ...on Manual System Specifications DodgeAttack System Specifications Rugged Interactive 2021 140 850 650 Score Box HUB 70 Mounting Points for Score Box Dimensions in mm Score Box HUB Dimensions in mm 850...

Page 26: ...Features Power Supply Specification for 5 9V...

Page 27: ...5VAC at full load 1000ms 30ms 230VAC 1500ms 30ms 115VAC at full load 3 0 1 0 3 0 1 4A 115VAC 1A 230VAC 30A 115VAC 65A 230VAC 30 60 Refer to Derating Curve 20 90 RH non condensing 40 85 10 95 RH 0 03 0...

Page 28: ...0 90 120 110 160 140 200 180 240 220 264 LOAD 90 100 80 70 60 50 40 Mechanical Specification Case No GSM60B Unit mm 125 31 5 50 POWER LED Inside Outside ID 2 1 x OD 5 5 C 70 10mm 11 0 5mm U 2464 16AWG...

Page 29: ...and or pinched cables No loose cables that could become a tripping hazard All long cables are supported at least every 50 cm Adequate strain relief provided for connection points Kept out of direct su...

Page 30: ...out by an appropriate instructor to all new users If anything unexpected occurs or problems persist after troubleshooting call Rugged Interactive directly on 44 0 1726 833 882 The volume can be adjust...

Page 31: ...play 4 If a pod has seven 7 or fewer working LEDs we recommend replacing the pod only applicable for CardioWalls 5 We suggest non solvent glass cleaning spray avoid spraying directly onto the pods Use...

Page 32: ...odgeAttack Congratulations Rugged Interactive 2021 Congratulations Congratulations on your new Rugged Interactive product Your customers are going to love this and it is a great addition to your venue...

Reviews: