background image

INSTALLATION INSTRUCTIONS - FLL/FXL LED FLOOD                                            SHEET 1 OF 2

SAVE THESE INSTRUCTIONS

93053561 Rev. A

WARNING!

 Fixtures must be grounded and installed in accordance with the National Electrical Code and all local codes.  Failure to do so may increase

the

RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.

  Install and use so fixture failures do not cause a hazard and use only in

environments for which the product is specifically marked.

WARNING!

 This product contains chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive harm. Thoroughly

wash hands after installing, handling, cleaning, or otherwise touching this product.

WARNING!

Dangerous voltage exist within the unit and all precautions usually observed in handling high voltage equipment should be observed when

replacing light engine or otherwise servicing luminares. Disregarding this warning could result in electrical shock and possible injury to the individual

installing or servicing this equipment. Installation and servicing should be done by qualified personnel.

CAUTION!

 Follow ALL luminaire recommendations, product markings, instructions, restrictions and warnings regarding luminaire operation and burning

position. Luminaire label shows electrical and environmental requirements and restrictions.

NOTE!

This luminare is designed for outdoor lighting applications with ambient temperatures not exceeding 40°C (104°F).

All electrical work must be done by a qualified electrician.

Turn off electric power to all affected circuits and allow to cool before installation or servicing.

A regularly scheduled maintenance program should be established to retain optimum light output and reduce heat retention. Dusting with a soft, clean,

dry cloth is normally sufficient for the optical system. Any accumulation of dust or dirt should be removed regularly.

Carefully read these instructions before installing product.  If you do not understand these instructions, before starting any work, contact your Hubbell

Lighting distributor or [email protected] or (864) 678-1000

Give instructions to facility owner/manager for future reference.

READ THOROUGHLY BEFORE INSTALLATION

Mounting The Fixture

Tools Required:

3/4" Wrench or Socket

Phillips Head Screwdriver

Turn off power to electrical connections.

Wiring must be performed by a qualified electrician.

Make electrical connections according to the local and National Electrical Codes.

Remove fixture from packaging along with hardware bag.

There are three wires coming out of this fixture:

       Black Wire - Line Voltage

       White Wire - Neutral

       Green Wire - Ground

Connect these wires to the supply wires using the wire nuts provided in the hardware bag.

Yoke Mount

(Fig. 1):

Use a minimum of two 3/8" diameter bolts or one 3/4" diameter bolt for mounting (Item 1 in Fig. 1).

Once fixture is aimed at the desired target, tighten the bolts on each side of the yoke (Item 2 in Fig. 1).

Knuckle Mount

(Fig. 2):

Mount fixture on 2 3/8" tenon, tighten down 4 set screws, and attach to tenon with attach nut and bolt (Item 3 Fig. 2).

Remove screws and cap.  Loosen bolt inside knuckle enough to adjust fixture. (Item 4 Fig. 2).

Once fixture is aimed at the desired target, tighten the bolt and replace cap and screws. (Item 2 in Fig. 2).

••


••







2

1

FIGURE 1

FIGURE 2

3

4

Hubbell Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000

Due to our continued efforts to improve our products, product specifications are subject to change without notice.

© 2016 Hubbell Lighting,  All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com   •  Printed in USA

Summary of Contents for FXL LED FLOOD

Page 1: ...reduce heat retention Dusting with a soft clean dry cloth is normally sufficient for the optical system Any accumulation of dust or dirt should be removed regularly Carefully read these instructions before installing product If you do not understand these instructions before starting any work contact your Hubbell Lighting distributor or techsupport hubbell ltg com or 864 678 1000 Give instructions...

Page 2: ...emoved NOTES For replacement LED Assemblies and Drivers please contact Hubbell Lighting for any replacement parts Contact your local distributor or agent to confirm parts availability prior to ordering replacement parts LOCATION OF SCREWS TO BE REMOVED Fig 2 Mounting The Visor PHOTOCONTROL OPTION GROUND COM LINE GREEN GRD BLACK RED WHITE NEUT BLACK LINE RED BLACK BLACK PURPLE GREY DRIVER LED BOARD...

Page 3: ... l accumulation de chaleur Un chiffon doux et propre est normalement suffisant pour dépoussiérer le système optique Toute accumulation de poussière ou saleté doit être retirée de façon régulière Lire attentivement les présentes instructions avant d installer le produit Si vous ne comprenez pas les présentes instructions communiquez avec votre distributeur de produits Hubbell Lighting ou avec techs...

Page 4: ...emplacement comme l ensemble à DEL ou le convertisseur d alimentation veuillez communiquer avec Hubbell Lighting Avant de commander veuillez communiquer avec votre distributeur ou agent local pour confirmer la disponibilité des pièces ROUGE NOIR ROUGE NOIR POURPRE GREY CARTE À DEL Fig 4a DIAGRAMME DE CÂBLAGE POUR PROJECTEUR FLL TERRE NEUTRE VIVANT VERT NOIR ROUGE BLANC NEUTRE NOIR VIVANT GRD CONVE...

Reviews: