5)
Replace all seals. Lubricate all seals
before and after installation.
1)
Remove the Snap Ring (Item 6)
above the Air Ring (Item 9).
2)
Slide the Air Ring off of the Cap
(Item 5).
3)
With the cap off of the body, screw
the handle and override stem (Item
3) down into the cap until the bottom
of the handle is touching the top of
the cap. Then, loosen the Set screw
(Item 2) in the Handle (Item 1),
remove the handle from the override
stem and remove the override stem
from the cap.
4)
Now, remove the air ring from the
cap by pulling upward.
6)
Reassemble the Override Cap Assy.
and place back onto the Body.
VI. RECOMMENDED MAINTENANCE
PROCEDURE
INTERVAL
Operate
Manually. Every
30
days.
Disassemble, inspect and lubricate.
Yearly or as required.
Replace
all
seals.
Every
two
(2)
years
or
as
required.