SMART-LINE
ECO-LINE
Installation Guide
32
10. Uranus & Neptun HK style – assembly of connection box for
outside/fresh air
1. Knock out the perforated part (A) on the required side using a hammer and fold
the two lugs (B) to the outside.
The FL shutter (C) can now be secured in any direction on top of the connection
box (D) by means of the tapping screws included in the set.
2. Insert the connection box (D) in the opening (A) and position as required.
The 2 lugs (B) determine where the holes Ø 3.5mm need to be drilled in the con-
nection box (D). The connection box must now be secured to the appliance by
means of the remaining tapping screws (E).
3. To prevent unwanted air from entering the insert, the connection box (D) should be
sealed at the appliance (F) (e.g. putty, aluminium tape, etc.).
The operating handle of the combustion air shutter is assembled in the facing so
that it can be easily accessed. The rope pull must not be bent or form narrow
loops. It also must not be passed over hot surfaces!