background image

2

PSA VRS/INOX M12

Before every use, please read the Safety

Instruction of the PSA-Fall protection 

anchorage point (PSA-VRS / PSA INOX 

STAR M12) carefully and make sure that 

you understand all substance. 

Improper use ore care of this eyebolt can 

result in bodily injury or property damage 

and eliminates any warranty!

1  Application and warning information

WARNING 

Improper assembled or damaged fall pro-

tection anchorage points and inappropriate 

use can result in deadly injury or lead to 

heavy injuries when load drops.

Inspect fall protection anchorage points 

before each use carefully!

•  PSA-VRS and PSA INOX STAR M12 must only 

be used by competent and trained people with 

adequate  knowledge,  and  outside  Germany  the 

corresponding country specific requirements must 

be utilised.

•  PSA-VRS M12 is not suitable for permanent 

outdoor use. Changing weather conditions can 

cause corrosion and wear of material. 

•  The user of the PSA-Fall protection anchorage 

point must be in good health to use this equipment. 

The hereby necessary certification can f.e. be ve

-

rified by a G41-checkup.

•  The PSA-Fall protection anchorage points must 

only be loaded with the stated number of persons.

•  To enable safety and appropriate information for 

all users in case of a resell to another country, the 

reseller must provide the user instruction, mainte

-

nance instruction for the regular inspection and the 

repairing in the country specific language.

2  Intended use of PSA-VRS and  

PSA INOX STAR

PSA-VRS and PSA INOX STAR M12 eyebolt can be 

used as anchor point, for fall protection harnesses. 

This anchor point (subsequently named PSA-Fall 

protection anchorage point) can also be attached per-

manent to a building, so that a fall protection harness 

can be hooked in. 
PSA-Fall protection anchorage points must only 

be used as fall arrest equipment (and not for lifting 

purposes).
PSA-Fall protection anchorage points 

are not desi-

gned to be used for permanent swiveling under 

load,

 because they can turn loose when turned under 

load. Please observe the following WLL: 

PSA-VRS M12 and PSA INOX STAR M12 are per-

missible for max.1 Person.

RUD-PSA (lifting points) fixing points are able to take 

all possible occurring forces in any loading directions 

if used in the intended way as fall arrest protection 

devices.

PSA-VRS M12 is not suitable for permanent outdoor 

use. Changing weather conditions can cause corro-

sion and wear of material. 
In consequence of the assembly method this product 

fulfills the requirements as described in DIN EN 795 

paragraph 3.2.1: 

Fall protection anchorage device type A

Fall protection anchorage device which includes when 

installed, either one or multiple stationary anchor 

point(s) and if for their fixing at the structural facility 

a stationary installed anchor point or a fixing element 

is necessary.
The PSA-VRS eyebolt and the PSA INOX STAR 

M12 must only be used for the in the user instruction 

specified purposes.

3  Installation information

3.1  General information

•  Capability of temperature usage: 

 

The PSA-Fall protection anchorage points PSA-

VRS and PSA INOX STAR M12 can be used in 

the temperature range between -40°C up to 280°C.

•  RUD PSA-Fall protection anchorage points must 

not  be  used  under  chemical  influences  such  as 

acids, alkaline solutions and vapours. Please ob

-

serve chapter 2, Intended use of 

PSA-VRS and 

PSA INOX STAR.

•  Pay attention during transport and storage of the 

PSA fall arrest anchor point that the thread will not 

be damaged.

HINT

The bolt is hold captive in the housing by 

4 compressions (indentations)

•  A plan must exist to accomplish rescue actions, in-

cluding all kinds of possible emergencies occurring 

with the work.

•  If the PSA-Fall protection anchorage point is used 

in mobile applications, it must be handed out to the 

user personally.

•  Modifications or repairing on the PSA-Fall protec

-

tion anchorage points must be carried out by the 

manufacturer only.

•  Store fall protection eyebolt at dry and non-corro-

sive environment only. 

  Correct maintenance and storage are important for 

the safety of the worker.

Summary of Contents for PSA-VRS

Page 1: ... person for the configuration of the declaration documents Michael Betzler RUD Ketten 73432 Aalen Aalen den 20 04 2018 Hermann Kolb Bereichsleitung MA _____________________________________________ Name function and signature of the responsible person Notifying department Kennn Identification No 0299 FA PSA Test and Certification department of DGUV Test Zwengenberger Straße 68 42781 Haan Testing re...

Page 2: ...or permanent swiveling under load because they can turn loose when turned under load Please observe the following WLL PSA VRS M12 and PSA INOX STAR M12 are per missible for max 1 Person RUD PSA lifting points fixing points are able to take all possible occurring forces in any loading directions if used in the intended way as fall arrest protection devices PSA VRS M12 is not suitable for permanent ...

Page 3: ... admission must be used In preparation please verify a calculation to make sure that the subgrade is able to absorb the re quested forces under the given circumstances loading direction quality grade of concrete etc 2 The bolting location for the PSA Fall protection anchorage points should be marked with paint 3 The PSA Fall protection anchorage point should be installed as follows Position above ...

Page 4: ...ll to max 6 kN Care should be taken when selecting components of equipment to avoid any risk of injury to persons or damage of property The safe function of a com ponent or a compromised equipment must not be effected Eliminate any damage of the PSA Fall protection anchorage point for example caused by loading on sharp edges The assembly of a PSA Fall protection anchorage point to a coupling eleme...

Page 5: ... only ne cessary if noticeable abnormalities can be seen In this juncture the 10 wear reduction regulation becomes valid Cracks at load bearing parts Function and damage of bolts and threads if it s visible The product identification at the PSA Fall protection anchorage point must be high visible and easy to read Please fill out the documentation card carefully and save it to write down regular in...

Page 6: ...ruction may cause serious personal injury and or damage to property The markings are according to DIN EN 365 Personal fall protection gear general requirements for user instructions and marking 5 Marking of the PSA VRS and PSA INOX STAR M12 Forge code Manufacturer Type denomination Size of thread M12 No of load bearing persons M12 1 Pers Traceability code EN Standard CE Marking Notifying departmen...

Reviews: