151
Graphical User Interface
RMON
Alarms
RMON > Alarms
The Alarms menu item sets and displays switch alarms.
Alarms Settings
■
Alarm Entry:
Sets the alarm group index. May be 1 to 65535.
■
Alarm Variable:
Enters a comment describing the event. May be up to 127 characters.
■
Sample Type:
Sets the method used for sampling the selected variable and calculating
the value to be compared against the thresholds. May be absolute (default) or delta.
■
Startup Alarm:
Selects whether to use rising (default) or falling startup alarms.
■
Rising Threshold:
Sets the rising threshold.
■
Rising Event:
Sets the event index used when a rising threshold is crossed.
■
Falling Threshold:
Sets the falling threshold.
■
Falling Event:
Sets the event index used when a falling threshold is crossed.
■
Interval:
Specifies the interval in seconds during which the data is sampled and
compared with rising and falling thresholds. May be 1 to 4294967295 seconds.
■
Owner:
Sets the RMON alarm group owner name.
Alarms Table:
Displays all alarm events on the switch. You may also delete entries.