Ruckus Wireless ZoneDirector 1100 Configuration Manual Download Page 2

VIEW Certified Configuration Guide: Ruckus Wireless 

721-1004-000-E.docx 
August 2014 

Copyright Notice 

© 2012-2014 Spectralink Corporation All rights reserved. Spectralink

TM

, the Spectralink logo and the 

names and marks associated with 

Spectralink’s products are trademarks and/or service marks of 

Spectralink Corporation and are common law marks in the United States and various other countries. All 
other trademarks are property of their respective owners. No portion hereof may be reproduced or 
transmitted in any form or by any means, for any purpose other than the recipient’s personal use, without 
the express written permission of Spectralink. 

All rights reserved under the International and pan-American Copyright Conventions. No part of this 
manual, or the software described herein, may be reproduced or transmitted in any form or by any 
means, or translated into another language or format, in whole or in part, without the express written 
permission of Spectralink Corporation. 

Do not remove (or allow any third party to remove) any product identification, copyright or other notices. 

Notice 

Spectralink Corporation has prepared this document for use by Spectralink personnel and customers. 
The drawings and specifications contained herein are the property of Spectralink and shall be neither 
reproduced in whole or in part without the prior written approval of Spectralink, nor be implied to grant any 
license to make, use, or sell equipment manufactured in accordance herewith. 

Spectralink reserves the right to make changes in specifications and other information contained in this 
document without prior notice, and the reader should in all cases consult Spectralink to determine 
whether any such changes have been made. 

NO REPRESENTATION OR OTHER AFFIRMATION OF FACT CONTAINED IN THIS DOCUMENT 
INCLUDING BUT NOT LIMITED TO STATEMENTS REGARDING CAPACITY, RESPONSE-TIME 
PERFORMANCE, SUITABILITY FOR USE, OR PERFORMANCE OF PRODUCTS DESCRIBED 
HEREIN SHALL BE DEEMED TO BE A WARRANTY BY SPECTRALINK FOR ANY PURPOSE, OR 
GIVE RISE TO ANY LIABILITY OF SPECTRALINK WHATSOEVER. 

Contact Information 

US Location 

European Location 

800-775-5330  

+45 7560 2850 

Spectralink Corporation 

Spectralink Europe ApS 

2560 55

th

 Street  

Langmarksvej 34 

Boulder, CO 80301  

8700 Horsens, Denmark 

[email protected]

  

[email protected] 

 

Summary of Contents for ZoneDirector 1100

Page 1: ...721 1004 000 Rev E August 2014 VIEW Certified Configuration Guide Ruckus Wireless ZoneDirector 1100 3000 5000 with ZoneFlex 7363 7372 7982...

Page 2: ...ion copyright or other notices Notice Spectralink Corporation has prepared this document for use by Spectralink personnel and customers The drawings and specifications contained herein are the propert...

Page 3: ...ting with the ZD through the Browser 9 Software Upgrade 10 View Configure System Settings 11 Chapter 4 General Settings 12 RADIUS Server Definition 12 Configure Services 13 Configure Admission Control...

Page 4: ...ummary Manufacturer Ruckus Wireless www ruckuswireless com Certified products Controllers ZD1100 ZD3000 ZD5000 APs ZF 7363 ZF 7372 ZF 7982 AP radio 2 4 GHz 802 11b g n 5 GHz 802 11a n Security None WE...

Page 5: ...reader will be referred to collectively as the 87 Series handsets Maximum calls tested per the VIEW Certification Test Plan The certified product may actually support a higher number of maximum calls...

Page 6: ...st by the tabs across the top of the list to find exactly what you are looking for Click the title to open the link Support Documents Spectralink 87 Series Wireless Telephone Administration Guide The...

Page 7: ...Telephones please refer to Best Practices Guide for Deploying Spectralink 84 Series Handsets for detailed information on wireless LAN layout network infrastructure QoS security and subnets For the Spe...

Page 8: ...configured with Wi Fi Standard QoS On the Admin menu navigate to Network Config WLAN settings Custom QoS Spectralink 84 and 87 Series handsets only support Wi Fi Standard QoS Network Topology Note Exa...

Page 9: ...Run the ZD s setup wizard 5 Alternatively the 3000 and 5000 models have a console serial port This can be reached using the settings 115200 baud 8 data bits 1 stop bit no parity and no flow control T...

Page 10: ...u bar at the top of the screen to navigate to the three options Monitor Configure and Administer Software Upgrade To upgrade go to Administer Upgrade The upgrade procedure starts with backing up your...

Page 11: ...Certified Configuration Guide Ruckus Wireless 721 1004 000 E docx August 2014 11 View Configure System Settings Navigate to Configure System System is where basic information about the ZD can be ente...

Page 12: ...igure an external radius server is not discussed in this document However configure a radius server details within ZD so that ZD can communication with external server as follows 1 Navigate to Configu...

Page 13: ...kground Scanning No testing was performed with tunnel configuration enabled Configure Admission Control Call admission control can be configured at different places in a ZD depending on what level of...

Page 14: ...The network devices must be configured to prioritize the traffic between the wireless and wired networks Below is a table showing the relationship between DSCP tags the prioritization method used by t...

Page 15: ...0 0 0 Internetworkcontrol cs7 0 38 56 0xE0 7 0 0 0 Networkcontrol The default values in the Ruckus system are Default voice settings 0xE0 1110 0000 which will map to DSCP 56 Network Control 0xC0 1100...

Page 16: ...0 65 heuristics inter packet gap Voice 15 275 heuristics packet length Video 2200 2201 heuristics packet length Voice 70 400 heuristics classification Video 50000 heuristics classification Voice 600...

Page 17: ...wn on the example screen Method 2 For broad deployment use the provisioning cfg files as described in the Spectralink 84 Series Deployment Guide The setting for the video tag is qos ip callControl dsc...

Page 18: ...guration Guide Ruckus Wireless 721 1004 000 E docx August 2014 18 2 Enter the DSCP value in decimal or as a hex number in the form 0x2e 3 Enter a value for Call control DSCP in decimal or as a hex num...

Page 19: ...ecurity option you will first name and describe the configuration Then you will select the security type and complete the required information for that type Security Open 1 Navigate to Configure WLAN...

Page 20: ...PSK 1 Navigate to Configure WLAN Create New 2 Enter the required values for Name ESSID Description and Type 3 Select Open under Authentication Options Method 4 Select WPA for Encryption Options Method...

Page 21: ...VIEW Certified Configuration Guide Ruckus Wireless 721 1004 000 E docx August 2014 21...

Page 22: ...urity WPA2 PSK 1 Navigate to Configure WLAN Create New 2 Enter the Name ESSID Description and Type 3 Select Open under Authentication Options Method 4 Select WPA for Encryption Options Method 5 Select...

Page 23: ...the steps below to create a WLAN with WPA2 Enterprise scheme 1 Navigate to Configure WLAN Create New 2 Enter the values for Name ESSID Description and Type 3 Select 802 1x EAP under Authentication Op...

Page 24: ...n the Advanced Options window 2 For Call Admission Control click the checkbox for Enforce CAC on this WLAN when CAC is enabled on the radio 3 For Proxy AP click the checkbox for Enable Proxy ARP 4 Sin...

Page 25: ...VIEW Certified Configuration Guide Ruckus Wireless 721 1004 000 E docx August 2014 25...

Page 26: ...kus config wlan bss minrate 5 5 ruckus config wlan no pmk cache for reconnect ruckus config wlan no qos directed multicast ruckus config wlan qos directed threshold 0 ruckus config wlan end message sa...

Page 27: ...tation 1 Navigate to Configure Access Points 2 In the main screen go to Access Point Groups 3 Click Edit for the AP group where CAC is required 4 Under Radio Settings go to Call Admission Control and...

Page 28: ...ill not be admitted to a network with 11N only Mode set to N only Individual AP Configuration At the AP level CAC is configured per radio The airtime denotes the percentage of total available BW that...

Page 29: ...ult your facility s RF site survey designed for voice traffic to determine if you have sufficient coverage to support all expected data rates The handset requires the following minimum dBm reading det...

Page 30: ...VIEW Certified Configuration Guide Ruckus Wireless 721 1004 000 E docx August 2014 30...

Reviews: