FIGURE 3  Typical AP sector elevation plane coverage, side view

Mounting Instructions

Connecting And Sealing the RJ-45 Cables

Connect and seal the RJ-45 cable(s) using the M25 data

cable glands shown in the Figure below.

WARNING! 

Do not use any PoE injector not tested and

approved by Ruckus Wireless to power the T310s Access

Point.

FIGURE 4  T310s LEDs and Ports

1. Feed the end of the cable through the sealing nut, rubber

O-ring, clamping ring assembly and cable gland base as

shown.

NOTE: Do not seat the clamping ring and rubber O-ring

into the gland body until the gland body has been

torqued to spec.

FIGURE 5  RJ-45 cable and cable gland assembly

2. Use a wide flat-blade screwdriver to remove the required

(PoE IN) blanking cap from the AP.

3. Connect the cable to the Ethernet port on the AP.
4. Tighten the cable gland base into the AP chassis to 7 N.m

or 62 in-lbs.

5. Wrap the clamping ring assembly around the rubber O-

ring. Make sure that the clamping ring assembly fully

encloses the rubber O-ring.

6. Seat the clamping ring assembly and rubber O-ring in the

cable gland base.

7. Hand-tighten the sealing nut.

Attaching the U-Joint Bracket to the Mounting

Bracket

1. Position the U-joint bracket on the mounting bracket.

NOTE: Mount the U-joint bracket in any direction on the

mounting bracket, preferably to allow AP azimuth

adjustments. Then the AP bracket allows AP elevation

adjustments.

FIGURE 6  U-joint bracket attached horizontally to the mounting bracket

2. Use four 1/4-28 bolt and washer sets (A) to mount the U-

joint bracket (B) to the mounting bracket (C). Tighten the

bolts to 9.5 N.m (7 ft-lbs).

3. Continue with 

Attaching the Mounting Bracket to a Flat

Surface

 or 

Attaching the Mounting Bracket to a Pole

.

Attaching the Mounting Bracket to a Flat Surface

1. Place the mounting bracket at the location on the flat

surface where you want to mount the AP. Use the holes

on the mounting bracket as a template to mark the

locations of the mounting holes.

FIGURE 7  Mounting bracket flat surface holes

2. Remove the mounting bracket from the flat surface.
3. Drill holes required for the mounting hardware.

NOTE: The hardware required for mounting to a wall

are not included in the mounting kit.

4. Attach the mounting bracket to the flat surface using the

mounting hardware.

5. Using the mounting hardware instructions, tighten the

hardware to secure the mounting bracket.

6. Continue with 

Mounting the Linkage Bracket to the U-

Joint Bracket

.

Attaching the Mounting Bracket to a Pole

1. Insert the open end of one steel clamp into the upper two

slots on the mounting bracket.

2. Take the other steel clamp and insert it into the lower two

slots on the mounting bracket.

NOTE: The clamps can be daisy-chained together to

accommodate larger poles.

3. Use the clamps to attach the mounting bracket to the

pole. Tighten the clamps to 3 N.m or 27 in-lbs, or per

manufacturer’s specifications.