1

Loosely assemble the hook bracket (A), the U-joint bracket (B), 
and the M8 bolt and washer set (C). 

Figure 9:

Attaching the hook bracket to the U-joint bracket

2

Loosely assemble the hook bracket, the U-joint bracket, and the 
M8 bolt and washer set. 

3

Set the elevation uptilt or downtilt required by the AP.

4

Tighten the M8 bolt to 27 N.m (20 ft-lbs).

S

TEP

 5: A

SSEMBLING

 

THE

 AP A

TTACHMENT

 

B

RACKET

 

AND

 

THE

 A

CCESS

 P

OINT

1

Place the AP attachment bracket onto the back side of the AP so 
that the four “B” screw holes on the bracket align with the four 
screw holes on the AP. Make sure that the longer end of the AP 
attachment bracket is on the same side as the AP antenna 
connectors.

Figure 10:

Attaching the AP attachment bracket to the AP

2

Use four M6 bolt and washer sets to mount the AP attachment 
bracket to the AP. Tighten the bolts to 9.5 N.m (7 ft-lbs).

S

TEP

 6: A

TTACHING

 

THE

 AP A

TTACHMENT

 B

RACKET

 

AND

 AP 

TO

 

THE

 H

OOK

 B

RACKET

1

Slide the AP attachment bracket and AP assembly onto the hook 
bracket.

NOTE:

 

MAKE SURE that the AP attachment bracket slides securely 

onto the hook bracket.

Figure 11:

AP attachment bracket and AP attached to the hook bracket

2

Torque the two hook bracket captive screws to 3 N.m or 27 in-lbs 
to secure the AP attachment bracket and AP.

S

TEP

 7: S

AFETY

-C

ABLING

 

THE

 AP

The 24” or 610 mm galvanized steel safety cable has a loop on one 
end and a retaining washer on the eye end.

1

Thread the safety cable around the main mounting bracket (A) and 
thread the eye end (B) through the loop end (C).

Figure 12:

Secured safety cable

2

Use one M6 bolt and washer set to attach the eye end of the 
safety cable (A) to a threaded boss on the back of the AP (B). 
Tighten the bolt to 9.5 N.m (7 ft-lbs).

Figure 13:

Attaching the safety cable to the AP

S

TEP

 8: E

ARTH

 G

ROUNDING

 

THE

 AP

1

Use terminal crimping pliers to crimp the customer-supplied 3-

5mm

2

 or 10-12 AWG earth-ground wire to the ring terminal 

located at (A).

Figure 14:

AP earth grounding location

2

Connect an earth ground to the AP as required by local 
regulations.

S

TEP

 9: P

OWERING

 

THE

 AP 

WITH

 AC

1

Separate the AC cable connector parts by unscrewing the boot 
from the cable gland and the cable gland from the connector 
housing.

2

Feed the end of the AC cable through the boot and cable gland.

3

Strip the AC cable as shown.

4

Insert the stripped part of the conductors into the appropriate 
terminals on the connector housing. The conductors are color-
coded and must be connected to the appropriate terminals as 
shown in Figure 15.
Typical AC wire colors:

-

 (Earth Ground): Green (US), Green/Yellow (EU)

- 1 (Neutral/Return): White or Gray (US), Blue (EU)
- 2 (Line/Hot): Black (US), Brown (EU)
- 3 (not used)

NOTE:

 

The color coding of wire conductors varies by region. Before 

completing this step, check your local wiring standards for guidance.

5

Using a small screwdriver, tighten the small screws around the 
connector housing to fix the connector pins into the terminals.

6

Mate the cable gland with the connector housing, and then hand-
tighten.

A

C

B

A

C

B

A

B

A

Summary of Contents for SC8800-S

Page 1: ...omer supplied earth ground wire 3 5mm2 or 10 12 AWG 1 2 13mm flat blade screwdriver or equivalent No 2 Phillips screwdriver Small flat blade screwdriver Torque wrench or torque screwdriver with sockets Long nose pliers Electrical wire stripping and terminal crimping pliers Pipe or pole OR a sturdy flat surface Electric drill with drill bits and customer supplied wall anchors flat washers and hex n...

Page 2: ...g hardware instructions tighten the hardware to secure the main mounting bracket 6 Continue with Step 4 STEP 3B ATTACHING THE MAIN MOUNTING BRACKET TO A WOODEN POLE 1 Place the main mounting bracket at the location on the mounting surface where you want to mount the AP Use the square holes on the main mounting bracket as a template to mark the locations of the mounting holes Figure 5 Wooden pole m...

Page 3: ...a loop on one end and a retaining washer on the eye end 1 Thread the safety cable around the main mounting bracket A and thread the eye end B through the loop end C Figure 12 Secured safety cable 2 Use one M6 bolt and washer set to attach the eye end of the safety cable A to a threaded boss on the back of the AP B Tighten the bolt to 9 5 N m 7 ft lbs Figure 13 Attaching the safety cable to the AP ...

Page 4: ...ide and the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the SC8800 S AP Both documents are available at https support ruckuswireless com Congratulations You have mounted the SC8800 S access point TROUBLESHOOTING REPLACING THE AP FUSES ONLY IF REQUIRED NOTE If the PWR LED does not turn on at all one or both of the AC power supply fuses inside the SC8800 S c...

Reviews: