Copyright © 2014 Ruckus Wireless, Inc.
Published January 2014, Part Number 800-70548-001 Rev C
Page 3 of 4
1
Loosely assemble the hook bracket (A), the U-joint bracket (B),
and the M8 bolt and washer set (C).
Figure 9:
Attaching the hook bracket to the U-joint bracket
2
Loosely assemble the hook bracket, the U-joint bracket, and the
M8 bolt and washer set.
3
Set the elevation uptilt or downtilt required by the AP.
4
Tighten the M8 bolt to 27 N.m (20 ft-lbs).
S
TEP
5: A
SSEMBLING
THE
AP A
TTACHMENT
B
RACKET
AND
THE
A
CCESS
P
OINT
1
Place the AP attachment bracket onto the back side of the AP so
that the four “B” screw holes on the bracket align with the four
screw holes on the AP. Make sure that the longer end of the AP
attachment bracket is on the same side as the AP antenna
connectors.
Figure 10:
Attaching the AP attachment bracket to the AP
2
Use four M6 bolt and washer sets to mount the AP attachment
bracket to the AP. Tighten the bolts to 9.5 N.m (7 ft-lbs).
S
TEP
6: A
TTACHING
THE
AP A
TTACHMENT
B
RACKET
AND
AP
TO
THE
H
OOK
B
RACKET
1
Slide the AP attachment bracket and AP assembly onto the hook
bracket.
NOTE:
MAKE SURE that the AP attachment bracket slides securely
onto the hook bracket.
Figure 11:
AP attachment bracket and AP attached to the hook bracket
2
Torque the two hook bracket captive screws to 3 N.m or 27 in-lbs
to secure the AP attachment bracket and AP.
S
TEP
7: S
AFETY
-C
ABLING
THE
AP
The 24” or 610 mm galvanized steel safety cable has a loop on one
end and a retaining washer on the eye end.
1
Thread the safety cable around the main mounting bracket (A) and
thread the eye end (B) through the loop end (C).
Figure 12:
Secured safety cable
2
Use one M6 bolt and washer set to attach the eye end of the
safety cable (A) to a threaded boss on the back of the AP (B).
Tighten the bolt to 9.5 N.m (7 ft-lbs).
Figure 13:
Attaching the safety cable to the AP
S
TEP
8: E
ARTH
G
ROUNDING
THE
AP
1
Use terminal crimping pliers to crimp the customer-supplied 3-
5mm
2
or 10-12 AWG earth-ground wire to the ring terminal
located at (A).
Figure 14:
AP earth grounding location
2
Connect an earth ground to the AP as required by local
regulations.
S
TEP
9: P
OWERING
THE
AP
WITH
AC
1
Separate the AC cable connector parts by unscrewing the boot
from the cable gland and the cable gland from the connector
housing.
2
Feed the end of the AC cable through the boot and cable gland.
3
Strip the AC cable as shown.
4
Insert the stripped part of the conductors into the appropriate
terminals on the connector housing. The conductors are color-
coded and must be connected to the appropriate terminals as
shown in Figure 15.
Typical AC wire colors:
-
(Earth Ground): Green (US), Green/Yellow (EU)
- 1 (Neutral/Return): White or Gray (US), Blue (EU)
- 2 (Line/Hot): Black (US), Brown (EU)
- 3 (not used)
NOTE:
The color coding of wire conductors varies by region. Before
completing this step, check your local wiring standards for guidance.
5
Using a small screwdriver, tighten the small screws around the
connector housing to fix the connector pins into the terminals.
6
Mate the cable gland with the connector housing, and then hand-
tighten.
A
C
B
A
C
B
A
B
A