background image

Copyright © 2013 Ruckus Wireless, Inc.
Published July 2013, Part Number 800-70544-001 Rev A

Page 1 of 2

ZoneDirector

 5000 and 

SmartCell Gateway

 200 

Rack Mount Kit Mounting Guide

This 

Rack Mount Kit Mounting Guide

 provides step-by-step 

instructions on how to install the Ruckus Wireless ZoneDirector 
5000 (ZD) or SmartCell Gateway 200 (SCG) into a server rack 
using the Ruckus Wireless 902-0178-0002 kit. Both ZoneDirector 
5000 and SCG are standard 2U form factor servers designed for 
mounting in a standard EIA 19” server rack. 

B

EFORE

 Y

OU

 B

EGIN

Before deploying your Ruckus Wireless product, verify that all 
items listed in “Package Contents” below are included in the 
package. If any item is damaged or missing, notify your 
authorized Ruckus Wireless sales representative. Also, make 
sure that you have prepared the required hardware and tools. 

NOTE: 

Some standard EIA 19” server racks have square or 

slotted mounting holes. The fasteners in this kit may not work 
with these racks, requiring the customer to supply rack-mount 
fasteners.

WARNING: 

Observe careful handling, kit may contain sharp 

edges.

NOTE: 

Using sliding rails could result in non-compliance with 

Seismic Zone 4 requirements of NEBS-3 certification.

T

HIS

 G

UIDE

 

IN

 O

THER

 L

ANGUAGES

请从以下网站获得该指南的简体中文版

 

https://support.ruckuswireless.com

.

Vous trouverez la version française de ce guide à l'adresse suivante 

https://support.ruckuswireless.com

.

こ の ガ イ ド の日本語版は 

https://support.ruckuswireless.com

 

で ご覧 く だ さ い。

 

가이드의

 

한국어

 

버전은

 

 

사이트

(

https://support.ruckuswireless.com

)

에서

 

확인하시기

 

바랍니다

.

Veja a versão em português (Brasil) deste guia em 

https://support.ruckuswireless.com.

Puede ver la versión en español (América Latina) de esta guía en 

https://support.ruckuswireless.com.

R

EQUIRED

 H

ARDWARE

 

AND

 T

OOLS

Medium flat-blade screwdriver

No. 1 Phillips screwdriver

11/32” nut driver

Ruler for measuring rack depth

12 customer-supplied server rack fasteners (only required if 
not using the factory-supplied rack mounting screws and 
rack bar nuts, E and F in Figure 1)

P

ACKAGE

 C

ONTENTS

A complete rack mount installation kit includes two rail 
assemblies and all of the items listed below:

Two outer rails with short front brackets (A in Figure 1); 
shipped attached to B in Figure 1

Two inner rails with safety stops (B in Figure 1); shipped 
attached to A in Figure 1

Four long brackets (C in Figure 1)

Two front locking brackets (D in Figure 1)

Twelve #10-32 x 3/4” (19mm long) rack mounting screws 
with nylon washers (E in Figure 1)

Four server rack bar nuts (F in Figure 1)

Eight #8-32 x 1/2” (12.7mm long) pan head screws with hex 
nuts and flat and lock washers (G in Figure 1)

Eight #8-32 x 1/4” (6.35mm long) pan head screws (H in 
Figure 1)

This 

Rack Mount Installation Guide

Figure 1: Rail assemblies and hardware

NOTE: 

This kit may include extra screws, nuts and washers. You 

may use the extras wherever required.

S

TEP

 1: S

EPARATE

 

THE

 R

AIL

 A

SSEMBLIES

 

INTO

 

O

UTER

 

AND

 I

NNER

 R

AILS

These are shown as A in Figure 1 and B in Figure 1, respectively.

1

Extend the inner rail (1 in Figure 2) until it locks.

2

Press down the spring safety lock (2 in Figure 2) to release 
the inner rail.

3

Remove the inner rail from the outer rail assembly (3 in 
Figure 2).

Figure 2: Separating the rail assemblies

S

TEP

 2: A

SSEMBLE

 

THE

 R

EAR

 B

RACKETS

 

ONTO

 

THE

 

O

UTER

 R

AILS

1

Measure the depth of your server rack. Use this 
measurement to adjust the length of the outer rail and 
bracket assemblies. 

NOTE: 

Leave the outer rail assemblies loose for now. You will 

tighten them after the outer rail assemblies are positioned in 
the rack.

2

If your rack depth is between 23.25 and 34 inches (59.6 and 
86.4cm), use four #8-32 x 1/2” pan head screw sets (G in 
Figure 1) and loosely attach two long brackets (C in Figure 1
to the two outer rails (A in Figure 1) as shown in Figure 3.

If your rack depth is between 29.5 and 34 inches (74.9 and 
86.4cm), also adjust the short front brackets (part of A in Fig-
ure 1) 
by loosening the #8-32 x 1/2” pan head screw sets (G 
in Figure 1), adjusting the front bracket positions as 
required, and retightening these screw sets.

3

If your rack depth is more than 34 inches (86.4cm), use four 
#8-32 x 1/2” pan head screw sets (G in Figure 1)and loosely 
attach two long brackets (C in Figure 1) to the two outer rails 
(A in Figure 1) as shown in Figure 3.
Then remove the short front brackets (part of A in Figure 1), 
and replace them with long brackets (C in Figure 1).

F

G

H

E

A

C

B

D

(Front

of

Rack)

(Rear

of

Rack)

(shipped attached

to each other)