VC-410 & VC410POE Ethernet Extender Manual
2.3 General Rules
Before making any connections to the bridge, please note the following rules:
•
Ethernet Port (RJ-45)
All network connections to the bridge Ethernet port must be made using
Category 5 UTP or above for 100Mbps, Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be use between the
MUX or HUB and an end node.
•
VDSL2 Port (RJ-11)
All network connections to the RJ-11port must use
24~26
gauge with
twisted pair
phone wiring. Recommended is at
least AWG26, better AWG24. Avoid to use any telephony
ribbon cables. Avoid to use any low diameter cables.
2.4 Connecting the Bridge
The bridge has two Ethernet ports which support connection to Ethernet operation and PoE
function. The devices attached to these ports must support auto-negotiation or 10Base-T or
100Base-TX unless they will always operate at half duplex. VC-410 & VC410POE fast Ethernet
port is used to connect to external power splitter(PoE) or build in power splitter of networking
devices such as IP CAM, VOIP, wireless AP, sensor scanner or other power splitter(PD side)
more than 30W.
Notes:
1. The RJ11 Line port is used to connect to telephone that is connected to VDSL2 CO and CPE
bridge (Point-to-point solution).
2. Slave device(CPE) must connect Master device(CO) through the telephone wire. Slave
cannot connect to Slave, and Master cannot connect to Master. Please confirm the
DIP switch
status
before the link is established.
9