![Ruby VC-410 Manual Download Page 21](http://html1.mh-extra.com/html/ruby/vc-410/vc-410_manual_1498617021.webp)
VC-410 & VC410POE Ethernet Extender Manual
Grounding the VC-410 & VC410POE
VC-410 & VC410POE is designed to enhance EMS performance by grounding. VC-410 &
VC410POE come with for grounding the switches. For optimal EMS performance, connection of
the left side of the VC-410 & VC410POE rear panel ground lug to the grounding point.
Before user installed power and device, please read and follow these essentials:
Use separate paths to route wiring for power and devices. If power wiring and device
wiring paths must cross, make sure the wires are perpendicular at the intersection point.
Note:
Do not run signal or communications wiring and power wiring through the same wire
conduit. To avoid interference, wires with different signal characteristics should be
routed separately.
You can use the type of signal transmitted through a wire to determine which wires should
be kept separate. The rule of thumb is that wiring sharing similar electrical characteristics
can be bundled together.
You should separate input wiring from output wiring.
We recommend that you mark all equipment in the wiring system.
21