background image

STEP 4 (Safety Cable Installation) 

LANGKAH 4 (Pemasangan Dawai Keselamatan) 

步骤

4 (

安装安全钢丝绳

 

 

1) Remove the safety cable screw from the hanging tube bracket. 

Keluarkan skru dawai keselamatan dari pendakap rod besi. 

移开吊杆支架上的安全钢丝绳螺丝(图

1

 

2) Arrange the safety cable as above image labelled with 2. 

Pasang dan ikatkan dawai keselamatan seperti gambar rajah 2 diatas. 

整理安全钢丝绳(图

2

 

3) Firmly screw the safety cable onto the hanging tube. 

Ketatkan skru dawai keselamatan pada rod besi. 

用螺丝拧紧吊杆上的钢丝绳(图

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING/AMARAN/

警告

Safety cable must be fixed correctly

May cause injury if ceiling fan drops. 

Pastikan dawai keselamatan dipasang dengan tepat, untuk mengelakkan kemalangan sekiranya kipas tertanggal. 

如果没有正确固定钢丝绳,有可能会导致吊扇下坠。

 

 

Summary of Contents for FORZA SERIES

Page 1: ...0 FORZA SERIES MODEL MODEL FORZA45 FORZA56 CEILING FAN KIPAS SILING USER MANUAL PANDUAN PENGGUNA...

Page 2: ...OUPLING COVER SENGKUAP BAWAH x 1 10 WIRE NUT PENUTUP WAYAR x 3 5 FAN MOTOR MOTOR KIPAS x 1 11 FLAT WASHER SESENDAL LEPER x 11 6 FAN BLADES BILAH KIPAS x 5 12 LIVE WIRE NEUTRAL WIRE WAYAR HIDUP WAYAR N...

Page 3: ...an kecederaan 3 Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning engineers ASHRAE or the local qualified...

Page 4: ...ipas tidak berfungsi dilarang cuba untuk membaiki kipas Pastikan kipas dihantar ke pusat servis kami yang sah untuk pembaikan 7 This appliance is not intended for use by persons including children wit...

Page 5: ...t position the two holes of plug aligning it to the shaft holes Place the lead wire and safety cable out the top of hanging tube Insert the hanging tube into plastic plug and aligning shaft holes to p...

Page 6: ...pin Pasang dan ketatkan rod besi pada roda getah dengan menggunakan bolt sesendal nat dan pin R yang dikeluarkan sebelum ini R NOTE PERHATIAN 1 Remember to lock the pin after tightening bolt Pastikan...

Page 7: ...safety cable as above image labelled with 2 Pasang dan ikatkan dawai keselamatan seperti gambar rajah 2 diatas 2 3 Firmly screw the safety cable onto the hanging tube Ketatkan skru dawai keselamatan p...

Page 8: ...an wayar elektrik utama dari kipas 3 All electrical connections must be in accordance with local and national electrical code standards If you are unfamiliar with proper electrical wiring connections...

Page 9: ...of coupling cover from the motor should be more than 5mm Jarak sengkuap bawah dengan motor haruslah lebih daripada 5mm 5 STEP 7 Blade Installation LANGKAH 7 Pemasangan Bilah Kipas 7 1 Insert the blade...

Page 10: ...AN Ceiling fan must be mounted above 2 5m from the floor and 1m from the wall to the blade Pastikan kipas dipasang pada jarak bilah kipas dengan lantai melebihi 2 5m dan jarak bilah kipas dari dinding...

Page 11: ...t kit assembly clockwise until the LED light kit assembly screws are firmly situated in the narrow ends of the keyhole slots Pasangkan set lampu LED pada piring lampu dan sambungkan wayar dengan plug...

Page 12: ...11...