2. Safety and Set Up
2.1. Before using your MELTA
®
Pro
2.2 Basic Electrical Connections (220 VAC Hz 50/60)
It is your responsibility and obligation to make sure your system:
• Has a pre start check carried out by the operator before each use.
• Has been located in such a way that the controls are away from the operator and that the housing
panel is securely closed at all times.
• Is the right capacity system for the intended use.
• Is connected to the proper power supply (see below).
• Is only used to do what MELTA
®
Pro is designed to do.
• Is not used by anyone untrained and unable to operate it properly.
• Is only used whilst wearing the correct PPE and clothing.
• Is not used in damp or wet environments.
An independent Risk Assessment should be carried out on this equipment before a decision is made
to use it underground.
• A 10 A 220 VAC electrical supply is required. Performance problems will occur with voltages less than 208 VAC or greater
than 240 VAC.
• Total amperage draw will depend on the final system configuration; length of hose.
• Auto shut off will occur when temperature reaches 218°C.
• Do not allow the system to share the same circuit with other electrical items, a dedicated supply is recommended.
• Do not use an extension cord or power boards.
• Ensure the machine has a current test and tag label.
• Ensure power lead is free from damage.