![RubbaFix MELTA Pro Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/rubbafix/melta-pro/melta-pro_operating-instructions-manual_1498301020.webp)
Australia (Toll Free): 1800 352 228
International: +61 2 8853 3000
See our full range online at
www.rubbafix.com
Appendix 2 Hose & Gun Card
L2
L1
ON/OFF BREAKER
TANK
FUSE
TANK
AIR BAG
2
1
2
1
TANK
RTD
HOSE
RTD
GUN
RTD
C1-8
C1-9 C1-10 C1-11
TANK HEATERS
CR1
Relay (Normally Open)
PUMP
READY
RELAY
PUMP
SWITCH
H7
GUN
INPUT
H6
A7
A6
M4
M3
C1-7
C1-6
C2-4
C2-3
HOSE/GUN
FUSE (F1)
AIR
BAG
L2
C1-2
HOSE HEATER
C1-5
TANK HEATERS
C1-4
GUN HEATER
HOSE
RELAY
H2
H5
ACC.
INPUT
C3-7
C3-6
POWER SWITCH
POWER SWITCH
TANK
RELAY
TANK
RELAY
L1
GUN
RELAY
TRIGGER
OUT
HOSE/GUN BOARD
A5
A4
ACC.
OUTPUT
C3-5
C3-4
ON/OFF BREAKER
POWER SWITCH
POWER SWITCH
TANK
FUSE
C1-3
H3
H4
HOSE/GUN
FUSE (F2)
MOTOR
FUSE (F3)
T
MOTOR
FUSE (F2)
CR3
CR1
CR1
CR2
Power Connection
2-Wire, 220 Volts
L1
220 V
L2
220 Volt Heaters Only
Electrical
Caution
220 VAC Schematic