Step 4:
Power on the repeater(s) and registration will start.
When the LED is steady green the repeater is successfully registered.
Screen shot
PARAMETERS
DESCRIPTION
IDX
System counter
RPN
SINGLE CELL SYSTEM:
The base has always RPN00, first repeater will then be RPN01, second repeater RPN02
and third RPN03 (3 repeaters maximum per base)
MULTI CELL SYSTEM:
Bases are increment by 2^2 in hex, means first base RPN00 second base RPN04 etc., in
between RPN01, 02, 03 addressed for repeaters at Primary base and 05, 06, 07 addressed
for Secondary base (3 repeaters maximum per base)
NAME/IPIE
Name and IPIE number of the repeater
DECT SYNC MODE
DECT Sync mode
–
Manually or Automatic
STATE
State of the repeater Enabled/Disabled
FW INFO
Firmware version
FWU PROGRESS
How many percentages of the firmware is loaded / Off if no firmware is being loaded
4.2.
Register repeater(s) “Manually”
NOTE:
Do not power on the repeaters before they have been added on the base station
NOTE:
When adding first repeater the base station(s) will reboot, this is because encryption is being enabled, the
same goes if all repeaters is deleted, then the system will reboot to disable encryption.