![RTscan RT230H User Manual Download Page 129](http://html1.mh-extra.com/html/rtscan/rt230h/rt230h_user-manual_1498179129.webp)
RT
23
0H
Us
er
Gu
id
e
129
g. Program the Central Area
Example: Set the percentage of central area to 20%
1. Scan the
Enter Setup
barcode.
2. Scan the
Specify Central Area
barcode.
3. Scan the numeric barcodes
“
2
”
and
“
0
”
.
4. Scan the
Save
barcode.
5. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
h. Program the Custom Prefix/Suffix
Example: Set the custom prefix to
“
CODE
”
1. Check the hex values of
“
CODE
”
in the ASCII Table. (
“
CODE
”
: 43, 4F, 44, 45)
2. Scan the
Enter Setup
barcode.
3. Scan the
Set Custom Prefix
barcode. (See the
“
Set Custom Prefix
”
section in Chapter 6)
4. Scan the numeric barcodes
“
4
”
,
“
3
”
,
“
4
”
,
“
F
”
,
“
4
”
,
“
4
”
,
“
4
”
and
“
5
”
.
5. Scan the
Save
barcode.
6. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
i. Program the Terminating Character Suffix
Example: Set the terminating character suffix to 0x0D
1. Scan the
Enter Setup
barcode.
2. Scan the
Set Terminating Character Suffix
barcode. (See the
“
Set Terminating Character Suffix
”
section in Chapter 6)
3. Scan the numeric barcodes
“
0
”
and
“
D
”
.
4. Scan the
Save
barcode.
5. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)