background image

OMNEO Configuration

 

 

 

6

 

 

 

10. 

Under 

Edit\Preferences\Catalog 

you can configure how the devices appear in the catalogue.  

Make sure 

Show device name 

and 

Show devices by type 

are checked. 

 

 

 

 

 

 

 

 

 

 

11. 

To configure your devices select them from the catalog on the left.  To change IP settings you 

will need to log in as an administrator.  This is done via the 

Device\Change User 

menu.   

Username: admin 

Password: password 

If the device is set to DHCP then the IP address fields will populate automatically.  You can 
check the 

Use Static IP Settings

 to manually enter in a fixed IP address, subnet and gateway. 

Summary of Contents for OMNEO

Page 1: ...MNEO Firmware Upload Tool UploadPlugins and check against the list below A minimum for an OMI card upgrade you will require the Microblaze FPGANios and Host Processor plug ins 1 Rev C OMNEO Requiremen...

Page 2: ...M or ADAM M 2 Connect the OMI card to your network via the Ethernet Connector J1 or the fibre connector 3 Using AZedit under Options Preferences Discovery select your network interface from the drop d...

Page 3: ...annel configuration and pass through data settings The OMI cards can use fixed addressing DHCP or Link Local addressing DHCP addresses for OMI and OKI devices can be provided from a third party DHCP S...

Page 4: ...subnets can be created 4 6 To set the MCII e controllers to provide DHCP go to Options DHCP Server Configuration Check the Enable DHCP Server box and enter the range for the addresses in the First IP...

Page 5: ...n list that will be used for the OMNEO configuration 9 Go to Device Add Search and any available OMNEO devices should show up in the list Highlight your devices in turn and click Add If you do not see...

Page 6: ...igure your devices select them from the catalog on the left To change IP settings you will need to log in as an administrator This is done via the Device Change User menu Username admin Password passw...

Page 7: ...evice from the Catalog on the left Select the appropriate channel from the channel columns in the middle of the screen Click the Destination Type down arrow and from the dropdown list select OKI 2 13...

Page 8: ...o use Keypanel data is only provided on channel 1 Channel 2 would be used for an auxiliary audio connection The Destination Channel Description will automatically populate if you have enter names into...

Page 9: ...Select the destination type as OMI XX representing number of channels so in this example OMI 64 17 Click the Destination Device Name field for your channel and then click the button Double click loca...

Page 10: ...igured the OMI card channel 1 to communicate with the OKI keypanel on channel 1 you must configure the OKI keypanel channel 1 to talk to the OMI card channel 1 The Destination Channel Description will...

Page 11: ...d find the appropriate channel status changes to green to indicate a positive connection A blank channel status indicates no configuration and a red channel status indicates a configured but not conne...

Page 12: ...Menu OMNEO Offers Keypanel OKI 2 Using your up and down arrow keys on the keypad you should be able to select the port in the intercom your configured OMI cards channel corresponds to Press the PGM o...

Page 13: ...done via the OMNEO Offers Keypanel AIO menu If it is set to disabled then the keypanel will be expecting an OMNEO IP connection If this is set to enabled the keypanel will be expecting an analogue mat...

Page 14: ...ion Selection Selection Selection Selection OMNEO Offers Keypanel OKI 2 None Port Alpha AIO Disabled Enabled Aux Input OMNEO CH 1 None Port Alpha OMNEO CH 2 None Port Alpha OMNEO Setup OKI Device Name...

Reviews: