1.
INTRODUCTION
These instructions describe the installation and operation
of the LCP-102 Level Control Panel, Version 1.0, in an
ADAM™, ADAM™ CS, or Zeus™ Intercom System.
Note that the LCP-102 is not compatible with the
CS9000 Series Intercom Systems. To complete the
configuration of some features, you may need to run your
CSedit, ADAMedit, or Zeus-edit Intercom System
Configuration Software, and you may need to refer to the
documentation for that software.
2.
LCP-102 DESCRIPTION
The LCP-102 combines the features of an Analog Trim
Panel, a Camera Delegate Panel, and a Program Assign
Panel in a single frame that is only 2 rack units high. You
can easily switch between its three panel modes and
make rapid configuration changes using the menu
selector on the front panel. In each mode, you can make
up to 64 assignments and then adjust the levels for those
assignments. For example, in TRIMS mode, you can
assign and adjust the analog input and output trims for up
to 64 intercom ports. In PAP mode, you can select the
program input source and set its level for each of 64
IFB's. In CDP mode, you can assign up to 64 intercom
ports to any combination of party lines and then adjust
the listen level for each participant on that party line.
The LCP-102 connects to the auxiliary data port of any
ADAM™, ADAM™ CS, or Zeus™ Intercom System,
and it also has a loop connector for connection to another
auxiliary device, such as another LCP-102, or a UIO-256
Universal Input/Output frame. Since a single LCP-102
provides trim adjustments for 64 ports, only one unit is
required to completely configure an ADAM CS or Zeus
system. For larger ADAM Intercom Systems, up to 15
additional LCP-102 frames can be connected via the loop
connectors.
4
User Manual, LCP-102 Level Control Panel
110
220
TELEX COMMUNICATIONS, INC.
MADE IN USA
SERIAL NO.
INPUT
LEVEL
OUTPUT
LEVEL
ADDRESS
KEY
PAP
CDP
TRIMS
LCP-102
LOOP
DATA
TM
Figure 1. LCP-102 Reference View
Menu Selector
Menu Display
Mode Indicators
DATA Connector for Connection
to Intercom System
LOOP Connector for
Connection to Additional
LCP-102's and/or a UIO-256
Fused Power Entry Module
with On/Off Switch
(100-240VAC, 50/60 Hz)
Displays and
Controls for
each of 16
Assignments