5/23
Проверил: Р.Ч./19.03.2015г
Vibration emission
0.1 m/s
2
, K=1.5 m/s
2
Wear hearing protection while operating the power tool.
The declared vibration total value has been measured in accordance with a standard test method and
may be used for comparing one tool with another.
The declared vibration total value may also be used in a preliminary assessment of exposure.
Warning
The vibration emission during actual use of the power tool can differ from the declared total value
depending on the ways in which the tool is used.
There is the need to identify safety measures to protect the operator that are based on an estimation of
exposure in the actual conditions of use (taking account of all parts of the operating cycle such as the
times when the tool is switched off and when it is running idle in addition to the trigger time).
USE
1.Preparing the Coating Material
The paints usually need to be diluted for use with the spray gun. Since information on sprayable
dilutions is seldom given on the material tin, you can use the guidelines in the viscosity table on
the following page (viscosity = consistency of the coating material).
Viscosity Table
Spray material
Runout Time in Seconds
Thinner-soluble primers
25-40
Thinner-soluble varnishes
15-40
Measuring the Viscosity
1. Stir the coating material thoroughly before measuring.
2. Dip the viscosity test cup completely into the coating
material.
3. Hold the test cup up and measure the time in seconds
until the liquid empties out.
Note: This time is called "
Runout Time in Seconds
".