background image

1

It’s Under Control

®

ZM-24

Installation and Operation Guide

70-210061-17  V1.0

Zigbee

®

 Transceiver Module

It’s Under Control

®

Summary of Contents for ZM-24

Page 1: ...1 It s Under Control ZM 24 Installation and Operation Guide 70 210061 17 V1 0 Zigbee Transceiver Module It s Under Control...

Page 2: ...Zigbee Transceiver Module ZM 24 2 Copyright 2008 Remote Technologies Incorporated All rights reserved...

Page 3: ...off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment...

Page 4: ...l near an open window etc Object and Liquid Entry Do not allow objects to fall or liquids to be spilled into the enclosure through openings Cleaning The unit should be cleaned only as recommended in t...

Page 5: ...liable for any damages caused by its products or for its failure of its products to perform including any lost profits lost savings incidental damages or consequential damages Remote Technologies Inc...

Page 6: ...Zigbee Transceiver Module ZM 24 6...

Page 7: ...ited Warranty and Disclaimer 5 Contents 7 Chapter 1 Welcome 9 Important Notes 9 Product Contents Unpacking 10 Chapter 2 Features 11 Chapter 3 Installation and Operation 13 Chapter 4 Specifications 15...

Page 8: ...Zigbee Transceiver Module ZM 24 8...

Page 9: ...ing them from any electrical outlet within communication range of other modules The ZM 24 units will then create a self healing mesh network which adapts to changes or problems with the communication...

Page 10: ...Zigbee Transceiver Module ZM 24 10...

Page 11: ...central processor from up to 1000 feet away using standard Cat5 cable Can be used in coordinator mode or create a self healing mesh network by adding modules configured in repeater mode Utilizes IEEE8...

Page 12: ...Zigbee Transceiver Module ZM 24 12...

Page 13: ...its together This will help eliminate RF reception drop out due to multi path interference installation 5 ft 50 ft 1 5m 15m 3 ft 1m Minimum 3 ft 1m Minimum 4 ft 1 2m Minimum connection options This di...

Page 14: ...Zigbee Transceiver Module ZM 24 14...

Page 15: ...Frequency Range 2 4Ghz 2 5Ghz Operating Temperature 32 F to 122 F 0 C to 50 C Operating Humidity 5 to 95 Non condensing Enclosure High impact molded ABS plastic black Mounting Detachable bracket Dime...

Page 16: ...Zigbee Transceiver Module ZM 24 16...

Page 17: ...e ZM 24 to a different area The Data LED never turns green Make sure the ZM 24 is wired correctly to the central control system and verify the control system is powered up Make sure the RTI universal...

Page 18: ...Zigbee Transceiver Module ZM 24 18...

Page 19: ...al number if applicable If you are having a problem with hardware please note the equipment in your system a description of the problem and any troubleshooting you have already tried If you are having...

Page 20: ...y to ship the ZM 24 for service Please pack it securely we suggest that it be insured Do not include accessories such as power cords or manuals unless instructed to do so You must pay any shipping cha...

Page 21: ...s Commission Notice 3 Installation Operation 13 Connection Options 13 Mounting 13 Limited Warranty Disclaimer 5 Product Contents 9 Safety Suggestions 4 Service and Support 23 Contact RTI 23 Shipment f...

Page 22: ...M 24 22 Remote Technologies Incorporated 5775 12th Avenue East Suite 180 Shakopee MN 55379 Tel 952 253 3100 Fax 952 523 3131 www rticorp com 2008 Remote Technologies Inc All rights reserved Printed in...

Reviews: