BDM-610000084 Rev B
Chapter 3: Connecting the cpuModule 53
PCI-104 PCI Bus Signals
The following are brief descriptions of the PC-104 PCI bus signals.
Address and Data
AD[31:00]
— Address and Data are multiplexed. A bus transaction consists of an address cycle followed by
one or more data cycles.
C/BE[3:0]#
— Bus Command/Byte Enables are multiplexed. During the address cycle, the command is
defined. During the Data cycle, they define the byte enables.
PAR
— Parity is even on AD[31:00] and C/BE[3:0]# and is required.
Interface Control Pins
FRAME#
— Frame is driven by the current master to indicate the start of a transaction and will remain
active until the final data cycle.
TRDY#
— Target Ready indicates the selected devices ability to complete the current data cycle of the
transaction. Both IRDY# and TRDY# must be asserted to terminate a data cycle.
IRDY#
— Initiator Ready indicates the master's ability to complete the current data cycle of the transaction.
STOP#
— Stop indicates the current selected device is requesting the master to stop the current
transaction.
DEVSEL#
— Device Select is driven by the target device when its address is decoded.
IDSEL[3:0]
— Initialization Device Select is used as a chip-select during configuration.
LOCK#
— Lock indicates an operation that may require multiple transactions to complete.
Error Reporting
PERR#
— Parity Error is for reporting data parity errors.
SERR#
— System Error is for reporting address parity errors.
Arbitration (Bus Masters Only)
REQ[3:0]#
— Request indicates to the arbitrator that this device desires use of the bus.
GNT[3:0]#
— Grant indicates to the requesting device that access has been granted.
System
CLK
— Clock provides timing for all transactions on the PCI bus.
RST#
— Reset is used to bring PCI-specific registers to a known state.
Interrupts
INTA#
— Interrupt A is used to request Interrupts.
INTB#
— Interrupt B is used to request Interrupts only for multi-function devices.
INTC#
— Interrupt C is used to request Interrupts only for multi-function devices.
INTD#
— Interrupt D is used to request Interrupts only for multi-function devices.
Summary of Contents for CML24BT cpuModules
Page 3: ...www rtd com ISO9001 and AS9100 Certified CML24BT cpuModules...
Page 5: ...BDM 610000084 Rev B v...
Page 6: ...vi CML24BT cpuModule BDM 610000084 Rev B...
Page 41: ...BDM 610000084 Rev B Chapter 3 Connecting the cpuModule 31...
Page 66: ...56 CML24BT cpuModule BDM 610000084 Rev B...
Page 86: ...72 CML24BT cpuModule BDM 610000084 Rev B...
Page 94: ...80 CML24BT cpuModule BDM 610000084 Rev B...
Page 108: ...92 CML24BT cpuModule BDM 610000084 Rev B...