Real Time Automation, Inc.
21
1-800-249-1612
ii.
INT: 1-200 characters
iii.
SINT: Not Used
Add Delimiters to ASCII Message
1)
Delimiters
:
Configure the characters to add to the message.
a.
Start: Use this feature to add a common starting delimiter(s) to messages being sent to
the ASCII device.
i.
The value of this first dropdown will either gray out or allow a delimiter to be
selected from the next dropdown.
ii.
Use this feature only if your ASCII device requires such delimiters.
iii.
All ASCII messages will receive the starting delimiters selected.
b.
End: Use this feature to add a common end delimiter(s) to messages being sent to the
ASCII device.
i.
The value of this first dropdown will either gray out or allow a delimiter to be
selected from the next dropdown.
ii.
Use this feature only if your ASCII device requires such delimiters.
iii.
All ASCII messages will receive the end delimiters selected.
Data Conversion
1)
Data Conversion:
a.
None (Default): Does no additional conversion on the data before sending it from the
gateway to the ASCII device.
b.
Prepend NULL: Adds a NULL character to the beginning of each message that is to be
sent from the gateway to the ASCII device.
c.
Postpend NULL: Adds a NULL character to the end of each message that is to be sent
from the gateway to the ASCII device.