![RST DLS-35 - 10 Series Instruction Manual Download Page 20](http://html1.mh-extra.com/html/rst/dls-35-10-series/dls-35-10-series_instruction-manual_1496809020.webp)
DLS–35
©
Dinel, s.r.o.
20
9 .
o
rder
code
10 .
c
orrect
Specification
exampleS
process connection:
DLS –35
10
– short bar, uncoated, lengths 50 or 100mm
11
– short bar, fully coated, fixed length 30 mm
14
– like
10
, but higher pressure resistance
20
– rod, partially coated, length 0.1 ... 1 m
21
– rod, fully coated (FEP), length 0.1 ... 1 m
22
– rod, fully coated (PFA), length 0.1 ... 1 m
23
– like
20
, but higher pressure resistance
24
– like
21
, but higher pressure resistance
25
– like
22
, but higher pressure resistance
30
– rod, uncoated (dismountable), length 0.1 ... 3 m
31
– rod, fully coated, length 0.1 ... 3 m
40
– rod, uncoated with ref. tube, length 0.1 ... 1 m
41
– rod, fully coated (FEP) with ref. tube, length 0.1 ... 1 m
43
– like
40
, but higher pressure resistance
44
– like
41
, but higher pressure resistance
50
– rope with weight, uncoated, length 1 ... 6 m
electrode length in mm
–
–
–
–
E
type of output:
N
– NPN (open collector)
P
– PNP (open collector)
connection method:
A
– stainless steel compression
gland (+ cable length)
B
– plastic threaded cable gland
(+ cable length)
C
– connector (socket not included
with sensor, recommended
type - see accessories.
V
– plastic cable gland with spiral
(+ cable length)
H
– plastic cable gland for protec-
tive hose (+ cable length)
type and design of electrode:
mech. design:
G
– pipe thread G 3/4"
M27
– metric thread M 27x2
M30
– metric thread M 30x1.5
NPT
– pressure thread NPT 3/4
cable
– cable length in m
N
– non-explosive areas
NT
- high-pressure design
DLS–35N–10– M27–N– B E100 cable 5 m
(N)
designed for use in normal areas;
(10)
uncoated short bar electrode,
(M27)
process connection by thread M27;
(N)
output type NPN;
(B)
plastic cable gland;
(E100)
electrode length 100 mm
DLS–35N–21–G–P–C E580
(N)
designed for use in normal areas;
(21)
rod fully coated electrode;
(G)
process connection by thread G3/4";
(P)
output type PNP;
(C)
connector;
(E580)
electrode length 580 mm.
DLS–35N–30–M30–P–C E1420
(N)
designed for use in normal areas;
(40)
rod uncoated electrode with reference tube;
(M30)
process connection by thread M30,
(P)
output type PNP;
(C)
connector;
(E1420)
electrode length 1420 mm.
Summary of Contents for DLS-35 - 10 Series
Page 2: ......
Page 25: ...25 Dinel s r o DLS 35 ...
Page 26: ...DLS 35 Dinel s r o 26 ...
Page 27: ...27 Dinel s r o DLS 35 ...
Page 28: ......