![RST Instruments RSTAR L900 Series Instruction Manual Download Page 19](http://html1.mh-extra.com/html/rst-instruments/rstar-l900-series/rstar-l900-series_instruction-manual_1497021019.webp)
L900 RSTAR Array Radio Series System
ELM0077I
RST Instruments Ltd.
Page 15
T
ABLE
A-1
M
ODBUS
A
DDRESSES FOR
D
IFFERENT
L
OGGER
T
YPES
Logger Type
MODBUS Address
Configuration
code
Channels per
Node Logger
DT2011B
128 (0x80)
0x11
12
DT2055B
129 (0x81)
0x55
20
DT2040
130 (0x82)
0x40
50
DT TILT
131 (0x83)
0x65
12
DT4205
132 (0x84)
0x42
20
DT2485 10 Channel
134 (0x86)
0x81
20
DT2485 40 Channel
133 (0x85)
0x85
50
DT2485 70 Channel
135 (0x87)
0x87
80
DT2485 100 Channel
136 (0x88)
0x80
110
DT2485 130 Channel
137 (0x89)
0x83
140
DT2485 170 Channel
138 (0x8A)
0x8F
180
DT2350
139 (0x8B)
0x35
20
DT2306
140 (0x8C)
0x23
*Contact RST
GAA
142 (0x8E)
0xAA
11
DTSAA
144 (0x90)
0x5A
*Variable
A
CKNOWLEDGING
D
ATA
T
RANSMISSION FROM
RTU
Clear the current data to allow the next transmission interval to proceed once all data
has been correctly received from the RTU. Use the command:
‘ND˽1<CR>’