15
The Instruments
IVT-10
IVT-20
Continuity Test
Threshold
< 200K
Ω
< 200
Ω
Diode Test
0.1~1.0V
Resolution
0.1V
Overvoltage protection
1000V AC/DC
Rotary Field Indication
Voltage range (LEDs)
100…750V
Frequency range
50…60Hz
Measurement
principle
Double-pole and firmly
hold the grip (L2)
Power supply
2 x 1.5V IEC LR03 AAA
size
Power consumption
Max. 32mA / approx.
94m
Ω
Operating Temperature -15ºC ~ 45ºC
Storage Temperature
-20ºC ~ 60ºC
Temperature Coefficient
0.2x(Spec.Accuracy/ºC
<18ºC >28ºC
Humidity
Max. 85% relative
humidity
Height above sea level
Up to 2000m
Pollution Degree
2
Type of protection
IP65
CE
EN61326 :
EN55011 :
Safety
EN61010-1 : 2010
EN61010-031 : 2008
EN61243-3 : 2010
UTE 18-510
EN60529 : 2000/AI2000
GS38
Functionality
EN61243-3 : 2010
EN61557-7 : 2007
EN61557-10 : 2001
EN 61557-1 : 2007
Weight
230g (IVT-10),
240g (IVT-20),
(incl. Batteries)
Dimensions