background image

Data Hold

 

The display will flash continuously if the measured 
signal is larger by 50counts than the display  
reading. However, it cannot detect across the AC 
and DC Current. 

Summary of Contents for ICM A1

Page 1: ...Instruction Manual ICM A1 AC DC Clamp Meter EN ICM A1...

Page 2: ...instrument To avoid false readings that can lead to electric shock and injury replace battery as soon as low battery indicator Do not use the instrument around explosive gas or vapor To reduce the ri...

Page 3: ...tery Earth Conforms to EU directives E Application around and removal from hazardous live conductors is permitted Do not dispose this electrical or electronic product in domestic household waste Cauti...

Page 4: ...3 Power on off Auto Power Off...

Page 5: ...Hold down and press ACA DCA Barrier for Hand Guard earth for the jaw with respect to The barrier on the JAW safe access of the hand held part do not hold in normal use over the barrier when is indicat...

Page 6: ...5 Auto ACA DCA Detection ACA DCA Due to the high sensitivity of the instrument perform DCA Zero in the same direction as measurement to avoid interference by an external magnetic field...

Page 7: ...6 Data Hold The display will flash continuously if the measured signal is larger by 50counts than the display reading However it cannot detect across the AC and DC Current...

Page 8: ...7 The instrument calculates the RMS value for 100ms as detecting a more than 5A current DCA ZERO Inrush Current...

Page 9: ...8 Low Pass Filter The cut off frequency of the low pass filter is about 160Hz with attenuation characteristic of approx 24db octave Backlight on off...

Page 10: ...9 Voltsense The number of dashes displaying on the LCD indicates the electric field intensity If no indication voltage could still be present...

Page 11: ...attempt to repair this instrument It contains no user serviceable parts Repair or servicing should only be performed by qualified personnel Cleaning Periodically wipe the case with a dry cloth and de...

Page 12: ...r requirement LR44 Size Button Battery 1 5V x 2 Battery Life 20 hours Maximum Conductor Size 22 diameter LVD EN61010 1 EN61010 2 030 EN61010 2 032 EMC EN61326 1 Installation category CAT 600V CAT Appl...

Page 13: ...ture 0 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage temperature 20 to 60 C 0 to 80 RH no batteries Temperature coefficient 0 2 x Specified accuracy C 18 C 28 C Pollution Degree 2 Shock vibrati...

Page 14: ...ounts For non sinusoidal waveforms Additional Accuracy by Crest Factor C F Add 3 0 for C F 1 0 2 0 Add 5 0 for C F 2 0 2 5 Add 7 0 for C F 2 5 3 0 Position Error of Clamp 1 5 of LCD reading DC Current...

Page 15: ...cifications are valid from 5 to 100 of each range Frequency Response 50 400Hz Sine Wave Low pass Filter Range Resolution Accuracy 50Hz 60Hz 60 00A 0 01A 3 5 5D 300 0A 0 1A 3 5 5D All specifications ar...

Page 16: ...15 Inrush Current Range Resolution 300 0A 0 1A Integration Time 100ms Trigger Current 5 0A VoltSense Voltage Range 80V 600V At the tip of clamp...

Page 17: ...teration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability...

Page 18: ...Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokoham...

Reviews: