RS PRO RSDPB4000 Series Quick Start Manual Download Page 4

 

 

 

 

RSDPB5000 Series High Voltage Differential Probe 

RSDPB5000 Series Summary 

 

Model 

Maximum Input Voltage 

Bandwidth 

Attenuation Rate 

RSDPB5150 

1500V 

70MHz 

50X/500X 

 

Overview 

RSDPB5000 series high voltage differential probes are designed for the 

measurement of high voltage differential signal, to meet the demand for floating 
measurement. The bandwidth can be as high as 100MHz, meeting the demand for 
majority of measurement systems. 

There are a variety of ranges to choose from, and their differential voltage 

measurement range can meet with the demand for majority of tested circuits. Users may 
go into test mode to adjust the offset voltage, and also to adjust automatically to 
prevent probes being disordered after years’ of use. The electronic touch buttons give 
them a longer working life. 

The  function of 5MHz bandwidth limit selection, whose frequency bandwidth fits 

the FETs switching frequency measurement in most switching power supplies, and they 
can filter out higher frequency noise and interference. With the sound & light alarming 
function, this can also be closed manually, with a USB power supply connector to make 
it easier and more flexible for use.

 

The probes are equipped with standard BNC input 

connectors, they can be used with any manufacturer oscilloscope ( oscilloscope input 
impedance should set to 1MΩ. when 50Ω is selected, the attenuation multiply 
attenuates double.) to test waveform of the tested circuits, there is an automatic save 
function, to prevent users re-operating in case of power supply drops. The probes have 
good capability of common mode noise suppression and can be widely used in the 
research and development, debugging or overhauling work for switching power supply, 
frequency converter, electronic ballast, frequency conversion electronic appliances and 
other electric power equipments. 
 

Application 

 

Floating voltage measurement 

 

Frequency converter 

 

Switching power supplies designs 

 

Welding, plating power supplies 

 

Induction heating, electromagnetic oven 

 

Motor driven design 

 

Electronic ballast design 

 

CRT displayer design 

 

Inverter, UPS power supplies 

 

Frequency conversion electrical appliances 

 

Power conversion and related design 

 

Electrical engineering experiment 

 

Low voltage appliances experiment 

 

Power electronics and electric drive experiment 

 

Summary of Contents for RSDPB4000 Series

Page 1: ...Quick Start RSDPB5000 RSDPB4000 High Voltage Differential Probe Series...

Page 2: ...2...

Page 3: ...e read this manual carefully before use Safety precautions 1 Be cautious of an electric shock 2 Pay attention to the maximum input voltage Please do not use in humid or in flammable and explosive envi...

Page 4: ...ng function this can also be closed manually with a USB power supply connector to make it easier and more flexible for use The probes are equipped with standard BNC input connectors they can be used w...

Page 5: ...ttenuation indicates different ranges such as RSDPB5150 500X indicate the maximum test voltage is 1500V 50X indicates the maximum test voltage is 1 5 0 V Oscilloscope attenuation factor should be set...

Page 6: ...scope oscilloscope input impedance should set to 1M Ifset to 50 the output attenuation is a half of the practical value 6 Power interface Standard USB type B interface supply power with standard USB a...

Page 7: ...262 Pincer Clips CK 281 CATIII 1000V Hook Clips CK 284 CATIII 1000V High Voltage Input differential lead CK 28 10A CATIII 1000V 10A CATIII 1000V 10A CATIII 1000V 10A CATIII 1000V Coaxial Output Line...

Page 8: ...Single ended to ground 5M Two inputs 10M Input Capacitance Single ended to ground 4pF Two inputs 2pF CMRR DC 80dB 80dB 80dB 100kHz 60dB 1MHz 50dB Noise Vrms 50X 50mV 500X 50mV 100X 200mV 1000X 1 2V P...

Page 9: ...lips CK 261 Approx 106 43 16 mm Pincer Clips CK 281 Approx 152 50 13 mm Hook Clips CK 284 Approx 121 23 23 mm Probe body dimensions 195 65 28 mm Probe body weight Approx 188 g Environment Characterist...

Page 10: ...probe body should be kept away from high voltage pulse circuits to reduce interference to the probe Test Mode Offset Setting Users may enter the test mode to adjust offset based on needs The probes m...

Page 11: ...DSO4000 Displays probe output Test bandwidth Standard signal Amplitude accuracy 0 75 rise time 3ns AC accuracy Generator or calibrator e g FLUKE WAVETEK 9100 Common mode rejection Digital millimeter A...

Page 12: ...ar 8 Repeat step 4 6 and calculate whether is within the accuracy ranges Model Attenuation Rate Signal source output voltage Probe expected output voltage RSDPB5150 50X 5V 100mV 2mV 500X 50V 100mV 2mV...

Page 13: ...o inputs of the digital millimeter 5 Enable signal source output respectively record voltage output values check with the following chart to calculate whether is within the ranges 6 Close the calibrat...

Page 14: ...scilloscopes When combined with the 50 load the attenuation will be 2 times as much RDPB4080 is recommend for use with our own manufactured PL 10 to expand the measuring with the electricity meter to...

Page 15: ...procedure Connect the probe to the oscilloscope with the BP 250 BNC TO BNC cable Adjust the vertical zero adjustment of the oscilloscope if necessary Select the attenuation rate and the vertical devia...

Page 16: ...h to clean Chemical must not be used to clean 3 Please put the probe in the package provided and put it in cool clean and dry places 4 Please put the probe in the package provided to prevent shock 5 D...

Reviews: