Crimp connectors

Crimp connectors included:

Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connector
into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of
the wire. Squeeze the handles together with enough force to crush the end of the butt splice.

Install Crimp Connectors

Keypads Installation

192-4543

 Installation

  

  

  

  

  

  

Open 

192-4543 

Keypad by loosening and removing the back case three-point 

security      screw at the bottom with the special tool.  

  

Use the provided drilling template to accurately locate and drill the required holes.

 

  

Use the screws provided to mount the back case on the wall. Be sure to draw the

 

     wiring through the large centre hole in back case, and keep level.

   Connect accurately the system wiring following the label enclosed on the rear.

 

  

Put the unit back and screw it on by using the special tool.

Template

3-point security screw

System wiring

Flat head phillips screws

Flat head phillips screws

Anchor bolts

Anchor bolts

2” (50.00mm)

33/10” (83.50mm)

18/5” (90.00mm)

2” (50.00mm)

2/3” (16MM)

1” (25MM)

CABLEHOLE DIA.

Product Center Line

SCREW SIZE

ANSI Standard #6

Body dia 5/32” (3.5mm)

Min.Lenth 1” (25mm)

PAN HEAD

3

1

2

3

4

5

E3AK8 Installation

  

Open E3AK8 Keypad by loosening and removing the back case three-point security 

     screw at the bottom with the special tool.  

  

Use the provided drilling template to accurately locate and drill the required holes. 

  

Use the screws provided to mount the back case on the wall. Be sure to draw the 

     wiring through the large centre hole in backcase, and keep level.

  

Connect accurately the system wiring following the label enclosed on the rear.

 Put the unit back and screw it on by using the special tool.

Template

Flat head phillips screws

Flat head phillips screws

Anchor bolts

Anchor bolts

3-point security screw

System wiring

Ø=(0.3”)8mm

Ø=(0.3”)8mm

Ø=(0.3”)8mm

Ø=(0.3”)8mm

Ø=(0.3”)8mm

Ø=(0.3”)8mm

83.50 mm

3.3”

90.00 mm

3.5”

  

1

  

2

  

3

  

4

  

5

Summary of Contents for 192-4543

Page 1: ...ACCESS RESET IS COMPLETE 2 SHORT BEEPS LOCKING COMPLETE 3 SHORT BEEPS INVALID ACCESS CONSTANT BEEPING BLUETOOTH DEVICE VANDALISED DOOR SENSOR IS ON Reset Procedures 1 Power off Access Control Keypad 2 Move the pin Jumper to P2 and P3 then power on 3 Hear a long beep to complete resetting procedures 4 Move the Pin jumper back to P1 and P2 to Normal setting 5 Login as Admin and check all users audit...

Page 2: ...oroneminutewhen 3failedpasscodeattempts IP65 1 192 4543 and E3AK8 Bluetooth Access Control Keypads E3AK8 OperatingVoltage 12to24VDC BluetoothModule BLE4 2BluetoothLowEnergy CurrentDraw Standbycurrent 26mA 12VDC 15mA 24VDC Workingcurrent Relayactive 27mA 12VDC 16mA 24VDC BluetoothOperatingDistance Upto50meters 164ft withoutblockingbymetal orconcretewall doorframes SmartphoneCompatibility Android5 0...

Page 3: ...wiring and pin setting Cable Buzzer 192 4543 E3AK8 Buzzer Cable Green Brown Green Brown Yellow White Blue Black Red RTE Request To Exit RTE Request To Exit DS Door Sensor DS Door Sensor COM Polarity Polarity Insensi ve Insensi ve V Power Supply V Power Supply Fail Secure Electrified Lock NO Fail Safe Electrified Lock NC Normal P1 P2 P1P2 P3 Jumper Pin Setting Reset P1P2 P3 P2 P3 Default P1 P2 P3 P...

Page 4: ...n by using the special tool Template 3 point security screw System wiring Flat head phillips screws Flat head phillips screws Anchor bolts Anchor bolts 2 50 00mm 33 10 83 50mm 18 5 90 00mm 2 50 00mm 2 3 16MM 1 25MM CABLEHOLE DIA Product Center Line SCREW SIZE ANSI Standard 6 Body dia 5 32 3 5mm Min Lenth 1 25mm PAN HEAD 3 1 2 3 4 5 E3AK8 Installation Open E3AK8 Keypad by loosening and removing the...

Page 5: ...er User ID and User Passcode to login User ID and User Passcode are given by the Administrator Login Success Login Failure indications will be shown as following Login Success You Have Successfully Logged In You May Now Unlock A Door Login Failure Login Failed Please Verify Your Login Information Or Contact Your Administrator 1 2 Device name Choose which device you want to unlock by pulling down t...

Page 6: ... Figure 4 and Figure 5 next page a Audit Trail is tracking last 1000 event logs including Tamper Alarm b Enter an user ID to search events for an user c Tap to export all events to excel file d Tap to refresh all events A Permanent Permanent access is given by default B Temporary Set specific access time period for guests and visitors C Number of Times To set number of access granted to user Pleas...

Page 7: ...ions Tamper Alarm If the device is vandalized the tamper alarm will beep immediately and won t go off until it s switched off by Administrator Door Re lock Time 6 seconds by default Edit the Door Re lock Time interval between 1 to 1800 seconds Auto Proximity Range Adjust Auto Proximity Range here The range is between 0 to maximum 20 and it may have different results under different circumstances D...

Page 8: ...on Website information Tap Settings to view or change setting functions in User s Settings Page See Figure 7 below Note Stand next to the 192 4543 or E3AK8 Bluetooth keypad when you want to connect the Smartphone to unlock or login the Bluetooth keypad can detect signal up to 50 meters 164 ft distance The response time of Bluetooth signal may vary depend on various mobile device models Bluetooth r...

Reviews: