4
5
Function
Range
Accuracy
AC Current
50~60Hz
400.0μA, 4000μA
±(2.5% rdg +10d)
40.00mA, 200.0mA
Resistance
400.0Ω
±(0.8% rdg +5d)
4.000kΩ, 40.00kΩ, 400.0kΩ
±(1.2% rdg +5d)
4.000MΩ
±(5.0% rdg +5d)
40.00MΩ
±(10.0% rdg +5d)
Capacitance
4.000nF
±(5.0% rdg +0.6nF)
40.00nF
±(5.0% rdg +30d)
400.0nF
±(3.0% rdg +15d)
4.000μF, 40.00μF, 200.0μF
±(5.0% rdg +25d)
Frequency
9.999Hz, 99.999Hz, 999.9Hz, 9.999kHz ±(2.0% rdg +5d)
Duty Cycle
0.5~99%
±(2.0% rdg +5d)
Max input voltage
600V AC/DC
Diode Test
Test current 1mA max., open circuit voltage of 1.5V typical
Continuity Check
Audible signal if the resistance is <100Ω
Display
4000 count 3 -3/4 digit LCD
Over range indication
LCD displays “OL”
Polarity
Minus (-) sign for negative polarity
Low Battery Indication
“BAT” symbol indicates low battery condition
Input Impedance
>7.5MΩ (VDC & VAC)
AC Response
Average responding
ACV Bandwidth
50Hz to 60Hz
Auto Power Off
15 minutes (approximately)
Fuse
mA, μA ranges; 200mA/600V fast acting Resettable Fuse
Batteries
Two 1.5V AAA
Operating Temperature
32°F to 104°F (0°C to 40°C)
Storage Temperature
14°F to 122°F (-10°C to 50°C)
Weight
145g
Size
104x55x32.5mm
Standard
IEC61010-1 CAT IV 600 V / CAT III 1000V CE Approved
Pocket Digital Multimeter / English
Pocket Digital Multimeter / English