17
Connect the EN 14594, AS/NZS 1716
approved Z-LINK
®
Air Supply Hose to a
breathing air source supplying EN 12021
or better quality air. Connect the respirator
quick disconnect fitting onto the Air Supply
Hose.
With air flowing through the respirator
adjust the air pressure at the point of
attachment to the recommended pressure
as specified in the Breathing Air Pressure
Table (page 15).
Connect the Air Supply Hose to the flow
control device.
Note:
Check the hose connections for any
air leaks and tighten if necessary - replace
any worn parts.
Airflow in the apparatus must be above
170lpm and the yellow indicator is not
visible when the flow drops below this
rate. DO NOT use the apparatus when the
indicator is not showing.
The Indicator can be positioned high or low
on the jaw so it is clearly visible.
SUPPLIED AIR
FIGURE 2.4
FIGURE 2.6
FIGURE 2.5
FIGURE 2.7
The Apparatus must be supplied with respirable air meeting the
requirements of EN 12021, AS/NZS 1715 or Higher Quality. The moisture content of the
breathable air should controlled within the limits in accordance with EN 12021, to avoid
the air freezing the apparatus. Do not use oxygen enriched air.
WARNING