background image

characteristics. Phase-related distortion and irregular  frequency peaks are conspicuously  absent. 
Electric  guitar amplifiers sound big and  natural,  without  unnatural  coloration,  when reproduced 
with  the  R-101.  The  R-101  ribbon  microphone  is  an  ideal  choice  for  strings,  woodwinds, 
percussion,  organ and amplified instruments. Acoustic pianos can be captured accurately without 
the comb filtering effects associated with condenser microphones.
 

Ribbons in the Digital World

Digital recordings benefit greatly from the properties inherent in ribbon microphones. Since A to 
D  converters  cannot  distinguish  between  the  sound  source  being  recorded  and  the  complex 
distortion  components  often  associated  with  condenser  microphones,  they  sometimes  have 
difficulty  tracking  the  signal,  resulting  in  ringing  and  edgy-sounding  tracks.  With  ribbon 
microphones,  ringing  is  almost  nonexistent  due  to the  ribbon’s  lack  of  distortion  artifacts  and 
high frequency peaks. A to D converters have less difficulty tracking the ribbon-generated signal, 
resulting in very smooth digital recordings free of microphone-related edginess.

User Guide

Using the R-101 Ribbon Microphone

There are a few important facts about ribbon microphones that are key in understanding how to 
use them intelligently.

1. The  R-101 is a 

side address

,  bi-directional  microphone  and its rejection in the dead  areas is 

very  strong.  Due  to this directionality,  the  R-101 should be placed at  1.3 times the  distance 
normally  used  with  omni-directional  microphones,  or  about  the  same  distance  used  for 
cardioid  microphones. This method  is used  to  achieve  the  same  ratio of  direct  to  reflected 
sound.

2. In the horizontal plane, the R-101 does not discriminate against the highs off axis; nor does it 

boost highs on axis. Therefore,  several  instruments or vocalists can be  placed in front  of the 
microphone without favoring the performer in the center of the group.

Several performers can be  grouped at  both the  front  and back of the  microphone,  with one 
proviso:  since  the  outputs  are  out  of  phase  at  the  front  and  back  of  the  microphone, 
cancellation  can  result  if,  for  example,  two  tenors  are  placed  at  opposite  sides  at  equal 
distances and they are singing in unison, so listen to the feed before committing to it.

3. When using the R-101 to record loud signal sources,  placing the microphone slightly off axis 

to  the  signal  source  (either horizontally  or  vertically) minimizes  the effect  of  high pressure 
sound levels displacing and possibly damaging the ribbon element.

4

Summary of Contents for R-101

Page 1: ...Royer Labs Model R 101 Mono Ribbon Velocity Microphone Operation Instructions Manual User Guide Assembled in U S A ...

Page 2: ...7 Finding and Working with the Sweet Spot 7 Other Types of Microphones 8 Proximity Effect and Working Distance 8 The Sound That Is More Real than Real 8 Microphone Techniques 10 General Tips for Using the Royer R 101 10 Recording Loud or Plosive Sounds 11 Stereophonic Microphone Techniques 13 Classic Blumlein Technique 13 Mid Side M S Technique 13 Care Maintenance 15 Features 15 Electrical Specifi...

Page 3: ...tional figure eight velocity type ribbon microphone designed for professional applications The figure eight pick up pattern allows the R 101 to be addressed from either side with equal sensitivity The in phase signal is achieved when the microphone is addressed from the front indicated by the ROYER logo The R 101 is reasonably tolerant to shock and vibration and performance is unaffected by change...

Page 4: ...here are a few important facts about ribbon microphones that are key in understanding how to use them intelligently 1 The R 101 is a side address bi directional microphone and its rejection in the dead areas is very strong Due to this directionality the R 101 should be placed at 1 3 times the distance normally used with omni directional microphones or about the same distance used for cardioid micr...

Page 5: ...ld likely continue to operate but performance could be compromised and re ribboning the microphone would be necessary to restore normal operation Amplification Considerations The performance of any non active ribbon microphone is directly affected by the microphone preamplifier it is paired with With so many mic preamps on the market how do you select one that gives the best possible performance w...

Page 6: ...ed for efficient operation of a ribbon microphone the noise characteristics of the preamp play a pivotal role in overall performance of the captured acoustic event 3 Load characteristics A suitable preamplifier should have input characteristics that impose the least amount of loading on the ribbon element In other words the input impedance should be high enough that its effect on the performance o...

Page 7: ... amplifiers and alternating current motors are the most likely sources of radiated noise Building wiring and electrical utility transformers are other likely sources A well designed microphone provides shielding to minimize the effects of stray magnetic radiation but complete isolation is impossible and the result can be hum or buzz Ribbon microphones can potentially manifest this condition to a g...

Page 8: ...ng of highs as the microphone is moved away from the sound source 3 Variation in ratio of direct to reverberant sound 4 Tendency of a microphone to favor the nearest sound source due to a combination of these items plus the influence of inverse square law Inverse square law states that for each halving of source to microphone distance the sound pressure level quadruples Other Types of Microphones ...

Page 9: ...n advantage is to make things sound more real than real For example many voices and certain musical instruments produce fundamental frequencies within the bass range below 150Hz or so but the fundamentals are weak If a microphone which has no proximity effect and a rising high frequency response is used on an upright piano or on a person with a thin weak voice the recorded sound is likely to sound...

Page 10: ...y sweet and clean when recorded with R 101s Place the microphone several feet from the instrument For larger string sections try placing the microphone slightly above the instrumentalists and angled down a distance of three or four feet will do the trick nicely Pianos sound excellent when recorded with R 101s and are free of phase related comb filtering The bass is full and rich while the top rema...

Page 11: ... the enemy Air movement is far more damaging to ribbon microphones than high SPL s Some sound sources can generate powerful blasts of air that should be avoided Kick drums and electric guitar and bass amplifiers are typical examples of sound sources that can produce harmful air currents One way to determine if the air pressure is excessive is to place your hand in front of the sound source the kic...

Page 12: ... the microphone s pickup pattern sound will not be affected 3 Side View of Kick Drum Miking Technique A Close miking angle mic so the sound pressure wave is off axis B Standard miking position 4 Horizontal Positioning Technique Applied to kick drum similar to that utilized for other loud or percussive instruments 12 ...

Page 13: ... i e each displaced 45 degrees from center Figure 1 Classic Blumlein or coincident miking technique Each microphone ultimately feeds one speaker in a stereo system and due to the directionality of the microphones the result is a very well defined stereo effect on playback For classical music particularly the reproduction can be very satisfying Mid Side M S Technique In the early days of stereo rad...

Page 14: ...ivering a wide stereo image As you reduce the level of the side microphone the width of the stereo image will narrow until with the side microphone turned all the way down you have just the mid mic panned center for a mono pickup If the outputs of the mid and side microphones are recorded on separate tracks the electrical connections shown in Figure 3 can be made at the mixer outputs and the adjus...

Page 15: ... microphone to liquids or caustic smoke 4 To avoid hum do not expose the microphone to strong alternating electromagnetic fields such as the power transformers in amps 5 Use a soft cloth to clean the microphone body A small amount of denatured alcohol can be used to remove fingerprints and other stains 6 Keep metal filings away from the microphone at all times 7 When not in use store the microphon...

Page 16: ...d Compact size Electrical Specifications Acoustic Operating Principle Electro dynamic pressure gradient Polar Pattern Figure 8 Generating Element 2 5 micron aluminum ribbon Frequency Range 30HZ 15 000HZ 3dB Sensitivity 48 dBv Ref 1 v pa Output Impedance 300Ω nominal balanced Rated Load Impedance 1500Ω or greater Maximum SPL 135dB Output Connector Male XLR 3 pin Pin 2 Hot All Royer monaural microph...

Page 17: ...embly Stainless steel internal baffle and dampener Weight 483g 17 oz Weight with Case 3 lbs 1 4Kg Dimensions 200mm L X 36mm W 7 9 L X 1 4 W Finish Matte Black Accessories shock mount aluminum case protective mic sock Optional Accessories pop screen To learn more about Royer products and their usage visit our website at www royerlabs com 17 ...

Page 18: ...Polar Pattern Frequency Response 18 ...

Page 19: ...om the date of original purchase and for the respective periods specified above Royer Labs will repair all Royer Labs products which are defective in material and workmanship EXCLUSIONS This warranty does not cover the following 1 Defects or damage caused by accident fire flood lightning or other acts of nature 2 Defects or damage caused by abuse misuse negligence or failure to observe the instruc...

Reviews: