background image

Page 

1

 of 

6

 

 

3245 Corridor Drive, Eastvale, CA 91752 

 

800.769.2414 

 951.360.1600  

 951.360.7500 (Fax

 
 

                                                       OWNER’S MANUAL 

INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE 

RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS)   

 

 

 

 

 

RETAIN THIS MANUAL FOR FUTURE REFERENCES. 

 
IMPORTANT.  Installing, Operating and Service Personnel: 

Safe and satisfactory operation of your equipment depends to a great extent on its proper installation. Installation 

must conform with local codes, or in the absence of local codes, to the 

National

 

Electrical Code, ANSI/NFPA-70

 

(latest edition). In Canada, Installation should conform to 

Canadian Electrical Code CSA-C22.2.

 

Electrical wiring from the electric meter, main control box or service outlet to appliance must be electrically 

grounded in accordance with local codes, or in the absence of local codes, with the 

National Electrical Code 

ANSI/NFPA- 70 

(latest edition) or the 

Canadian Electrical Code CSA-C22.2. 

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel 

who are familiar with and experienced in state/local installation codes.  

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual 

and are familiar with the functions of the equipment.  

Service of the equipment should be performed by qualified personnel who are knowledgeable with ROYAL 

RANGE OF CALIFORNIA, INC.  

SHIPPING DAMAGE: 

 

The equipment is inspected and crated carefully by skilled personnel before leaving the factory. The transportation 

company assumes full responsibility for safe delivery upon acceptance of this equipment. Upon receipt of shipment, 
immediately  unpack  and  check  for  possible  shipping  damage.  If  the  equipment  is  found  to  be  damaged,  save  the 
packaging material and contact the carrier immediately.  

RATING PLATE: 

 

The rating plate is located on the right side of the appliance. Information on this plate includes the model, serial 

number, power input, ampere draw and clearances. This data is essential for proper identification when communicating 
with the factory regarding a unit, requesting parts or information. 

ROYAL  RANGE  COOKING  APPLIANCES  MUST  BE  CONNECTED  ONLY  TO  THE  POWER  INPUT 
IDENTIFIED ON THE RATING PLATE. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

July 2017 

Email: [email protected] 

 www.royalranges.com 

FOR YOUR SAFETY 

DO NOT STORE OR USE GASOLINE OR 
OTHER FLAMMABLE VAPORS OR 
LIQUIDS IN THE VICINITY OF THIS OR 
ANY OTHER APPLIANCE. 

WARNING 

Improper installation, adjustment, alteration, 
service or maintenance can cause property 
damage, injury or death. Read the installation, 
operating and maintenance instructions thoroughly 
before installing or servicing this equipment.  

Summary of Contents for RHPE-12-1

Page 1: ... the functions of the equipment Service of the equipment should be performed by qualified personnel who are knowledgeable with ROYAL RANGE OF CALIFORNIA INC SHIPPING DAMAGE The equipment is inspected and crated carefully by skilled personnel before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment Upon receipt of shipment...

Page 2: ...n the absence of local codes to the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 2 ELECTRICAL CONNECTION WARNING Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and or other local electrical codes WARNING Disconnect electrical power supply and place a tag at the disconnect switch to indica...

Page 3: ... Regulates the amount of heat needed to maintain the set temperature Each 12 section of the griddle has its own thermostat with a temperature range of 200 F to 500 F HOT PLATE ELEMENTS Hot Plate elements are most efficient when used with utensils having a maximum inside diameter of 10 254 mm or a minimum inside diameter of 9 NOTE It is important that the utensils used have a flat bottom that sits ...

Page 4: ...ctive oil coating applied at the factory 2 Rinse with a mixture of cup vinegar to one quart water 3 Apply unsalted solid shortening or liquid frying oil evenly over the entire griddle surface 4 Turn ON all griddle thermostats to 350 F wait until the shortening oil begins to smoke then turn the thermostats OFF 5 Carefully rub the now melted shortening into the griddle surface with a soft cloth movi...

Page 5: ...son with shortening oil WARNING Do not apply cold water to a hot griddle This promotes griddle warping and can cause the griddle to crack PERIODIC CLEANING Wipe exposed cleanable surface when cool STAINLESS STEEL PARTS Do not use steel wool abrasive cloths cleaners or powders to clean stainless steel surfaces All stainless steel parts should be wiped regularly with hot soapy water during the day a...

Page 6: ...24 4 8 20 37 20 40 40 18 33 18 35 35 RHPE 36 6 12 35 35 35 61 61 32 32 32 53 53 RTGE 12 3 4 17 17 15 15 RTGE 24 6 8 17 27 17 33 33 15 24 15 29 29 RTGE 36 10 2 29 29 29 50 50 25 25 25 43 43 STANDARD VOLTAGES 208 VOLTS 240 VOLTS 50 60 Hz SINGLE OR THREE PAHSE MODEL 208 VOLTS 3 PH 240 VOLTS 3 PH 208 VOLTS 1 PH 240 VOLTS 1 PH TOTAL KW ...

Reviews: