10
A
B
C
D
E
R-6500TR
49
16 1/4 35 3/8
50
70 3/4
R-4500TR &
42
16 1/4 31 7/8
45
63 3/4
R-4500TRH
R-3500TR &
37
16 1/4 29 3/8 41 1/2 58 3/4
R-3500TRH
NOTE: DIMENSIONS SHOWN IN INCHES.
Figure 4. Fireplace Dimensions, Locations,
and Space Requirements
Clearance Requirements
The top and back of the fireplace are defined by stand-offs.
MODELS
RECESSED
DEPTH
R-6500TR, R-4500TR & R-4500TRH, R-3500TR & R-3500TRH
16 1/4
*The clearance to the ceiling is measured from the top of the unit, excluding
the standoffs and collar. (see Figure 42).
The minimum clearance to a perpendicular wall extending past the face of the
fireplace is 3 inches (76.2mm).
The back of the fireplaces may be recessed into combustible construction, as
shown below.
Minimum Clearances from the Fireplace to
Combustible Materials
Glass Back of Sides of
Top of
Front Floor Fireplace Fireplace Fireplace
Ceiling*
36 inches 0 1/2 inch 1/2 inch
(914 mm)
(13mm)
31 inches
(787mm)
(13mm)
R-3500 TR &
R-3500 TRH: 1
1/2
(38mm)
R-4500TR &
R-4500TRH: 3
1/4
(83mm)
R-6500TR: 3
1/4
(83mm)
3
Installing the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
Step 1
Locating the
Fireplace