Trouble Shooting

PROBLEM

SOLUTION

Elec

trode and burners

 are wet

Igniter battery is dead or 

backwards

Igniter Pin cracked or broken 

- sparks a crack

Wipe dry with cloth.
Check that the battery is inserted correctly in the 

igniter or replace the battery.

 

Make sure the 

plastic wrap on the battery has been removed

.

Please contact Living source to request the

 

parts.

Residue on Igniter Pin

No Gas Flow

Check for residue on the igniter pin or 

Thermocouple. If dirty,thoroughly clean the area.

Check that the electronic Ignitor Cap is tightly 

fitted to the spring.If loose,please adjust the

spring accordingly.

Check if the LP gas tank is empty. If empty,

replace and refill. If the propane tank is not empty, 

refer to Problem: Sudden drop in gas flow on the 

following page.

Coupling nut and regulator not 

fully connected

Turn  the  coupling  nut  about  one  half  to  three 

fourths a turn, until you feel a solid stop.

 

Do not 

use tools, tighten by hand only.

Obstruction of gas flow

Check for bent or kinked hose.

Spider webs or insect nest in 

the venturi

Clean the venturi.

Burner ports clogged or 

blocked

Reference Problem: Irregular flame pattern on the 

following page. Clean the burner ports as 

described there.

Hose from gas fire table 

is

 pinched

Make sure the hose is not pinched between the 

fire table and the source of the gas.

Flame is being obstructed at 

burner ports or mixing chamber 

of the burn tube is blocked or 

obstructed

Make sure that the gas ports on the burner are 

free of any lava rocks/fire glass so that the 

flame can flow naturally.Clear out the mixing 

chamber located before the Venturi.

Out of Gas

Check for gas in the LP gas tank.

Excess flow safety device

 may 

have been activated

Turn control knob to OFF, wait 30 seconds and 

light outdoor fire table.if flames are still too low, 

reset the excessive flow safety device by turning 

off the control knob and LP gas tank valve. 

Disconnect regulator. Turn burner control knob to 

HIGH. Wait at least 5 minutes. Turn burner control 

knob off. Reconnect regulator and perform a leak 

check at tank connection. Turn LP gas tank valve 

on slowly, wait 30 seconds and then light outdoor 

fire table

.

Irregular flame pattern, flame

 does 

not run the full length of the burner

Burner ports are clogged or 

blocked

Clean  burner  ports.Do  this  by  inserting  a 

paperclip  into  each  of  the  burner  ports  to 

ensure  they  are  not  clogged.

WARNING: Make  sure  burner  is  not  on,  and 

has  had sufficient time to cool before touching it.

High or gusting winds

Increase flame to HIGH setting.

Low on LP gas

Replace or refill LP gas tank.

Excess flow valve tripped

Refer to Problem: Sudden drop in gas flow

.

Flame seems to lose heat when 

burning in cold weather

 - 

temperature below 50°F

Ice has built up on the outside 

of the LP gas tank because 

the vaporization process is too 

low

Turn the control knob and the LP gas tank to OFF. 

Replace with a spare LP gas tank and resume 

burning. Store the spare LP gas tank in a well 

ventilated area, away from children.

Burner will not light using igniter

Burner will not light with match

The fire table emits a lot of

 

black smoke when in use

Sudden drop in gas flow, or a

 

reduced flame height

Flame blow out

CAUSE

Summary of Contents for TM21RD41FPT1

Page 1: ...store please visit sunvilla com or contact our Customer Service Department at cs sunvillahome com or call 1 888 690 9800 8am 5pm PST Monday Friday IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY THE ITEM IS INTENDED FOR OUTDOOR DOMESTIC USE ONLY NOT FOR COMMERCIAL USE ITM ART TM21RD41FPT1 ...

Page 2: ...CONTENTS Warnings 1 4 Assembly 7 8 Operation 9 10 Maintenance Storage 11 Trouble Shooting 12 13 Warranty Information 14 Diagram 5 6 ...

Page 3: ...llowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you For outdoor use only Never use in the unventilated or enclosed areas DANGER IF YOU SMELL GAS Shut off gas to the appliance Extinguish any open flame If odor contin...

Page 4: ...nks of the U S Department of Transportation or the National Standard of Canada CAN CSA B339 LP gas tanks spheres and tubes for Transportation of Dangerous Goods and Commission Discontinue use if any part of the propane tank is damaged Rust and dents may be hazardous and should be inspected by a gas supplier The installation of this unit must adhere to local codes or either the National Fuel Gas Co...

Page 5: ...r and free from combustible material gasoline and other flammable vapors and liquids Be aware of the hazards of high temperatures and stay away from the unit to avoid any burns or injury This heating appliance should NOT be used on plastic artificial wood desks or any desk DO NOT add water into the unit DO NOT disconnect any part while the unit is in use DO NOT operate on a boat or vehicle DO NOT ...

Page 6: ... unit If the flame goes out while burning turn the gas valve off Wait 5 minutes before repeating the initial lighting procedure Once you have a flame started hold down the control knob for 1 minute Inspect all elements of this heating unit before each use If there is damage the burner must be replaced Keep the hose out from any pathways to eliminate any accidental damage if external tank Installat...

Page 7: ...e 1 04 Ignition Pin 1 Burner Plate 1 06 Main Frame of Fire Table 1 Lava Rock 4 Burner 1 09 Nozzle 1 10 Corrugated Pipe 1 11 Swithing Valve 1 12 Regulator Valve with Gas Hose 1 Control Knob 1 14 Igniter 1 15 Foot 4 Warning Label 1 Wing Screw with Nut 1 Metal Stand 1 01 03 05 07 08 13 16 17 18 ...

Page 8: ...Page 6 of 14 Parts List Item Picture Description A Lava Rocks 4 box B AAA Battery 1 pc C Main Frame of Fire Table 1 pc Qty ...

Page 9: ...Metal Stand Turn the preassembled Wing Screw 17 in a clockwise direction in to the Nut to secure the Propane Gas Tank tightly Step 3 Turn the Cylinder Valve 21 on the tank clockwise direction to TURN OFF SUPPLY of the LP Gas supply Attach the pressembled Regulator 12 19 from the Fire Table to the Cylinder Value 21 by turning the Black Regulator Coupling Nut 20 clockwise Make sure it is fastened se...

Page 10: ... the battery tightly Step 5 pour Lava Rocks over the Burner Ring The Guard MUST NOT BE BLOCKED Do not place more than 1 4 inch depth of lava rocks above the burner holes Do not place more than 26 4lb of lava rocks above the burner holes WARNING Fire Table and LP Cylinder must be at a minimum of 60 inches apart Assembly Instructions WARNING To ensure proper function the Guard 01 on the Burner 08 sh...

Page 11: ...sconnect propane gas tank and do not use the appliance until the leak is repaired The Fire Table has a Door Open the door and inspect the Gas Hose before use the Fire Table If there are signs of wear or abrasion on the hose you must replace the Gas Hose And the Gas Hose must be supplied directly by manufacturer Stand away from the Fire Table Column for the initial 20 minutes after igniting Lava ro...

Page 12: ...he Control Knob 13 to allow gas to flow for 15 seconds 6 If ignition doesn t occur within a few seconds release the Control Knob 13 and rotate to the OFF position Wait for 5 minutes for gas to clear and then repeat the above lighting instructions 7 Once the Fire Table Column is lit the flame intensity may be controlled by turning the Control Knob 13 between the LOW and HIGH positions Operation NOT...

Page 13: ... Blotany liquid spills with a clean dry cloth to avoid spreading of the spill to the rest of the table Immediate cleaning of stains blotting of spills also prevent absorption of such stains spills into the surfaces compared to if such stains are left for extended periods on these surfaces Cover your product with an outdoor Protective Cover when not in use to protect it from the elements Avoiding e...

Page 14: ...f any lava rocks fire glass so that the flame can flow naturally Clear out the mixing chamber located before the Venturi Out of Gas Check for gas in the LP gas tank Excess flow safety device may have been activated Turn control knob to OFF wait 30 seconds and light outdoor fire table if flames are still too low reset the excessive flow safety device by turning off the control knob and LP gas tank v...

Page 15: ...ve with the silver backing Once this has been done please test the unit You may have to reset the gas valve once again as the safety mechanism may have been set off by the new components introduced Resetting Your Gas Valve Completely detach the propane tank from the table Do not forget to turn the propane tank valve down Turn the heat knob to high and leave it on that setting for about two to thre...

Page 16: ...mer Defects or damage caused by the use of other than genuine parts are not covered under this warranty This warranty shall be effective from the date of purchase as shown in the purchase receipt The manufacturer warranty will be voided by and manufacturer disclaims any responsibility for the following actions but not limited Modification of the unit and or components including the gas valve assem...