60
I. ENGINE FAILS TO START
1) Stop switch in ‘OFF’ Position ................................
Push stop switch to ‘ON’ position.
2) Vent pipe blocked / pinched while routing ....
Clean vent pipe or route proeprly.
3) Spark plug cap / lead not connected .............
Fix cap / lead firmly
4) Spark plug electrode dirty / fouled ................
Clean spark plug
5) Spark plug insulation cracked .........................
Replace spark plug
6) Clutch slipping .....................................................
*Adjust clutch cable free play
7) Side stand in extent position .............................
Retract side stand
8) MIL glowing continuously ..................................
*Check Malfunction
TROUBLE SHOOTING
CAUSES
REMEDIES
* Contact Royal Enfield Authorised Dealer
WARNING
The trouble shooting section of this Owner’s Manual is intended solely as a guide to diagnosing problems.
Carefully read the appropriate sections of this manual before performing any work. Repair and maintenance
operations not listed in this Owner’s Manual should be performed by your Royal Enfield Authorised Dealer only.
Improper repair and/or maintenance could result in the motorcycle not functioning properly, serious injury or death.