ROXELL - 0715
BRIDOLAY-
-
EU
7
PROBLEM
LAMP
MAN/
AUT.
CAUSE
CORRECTIVE ACTION
5. Circuit
does not
run.
NO
AUT.
a. Panel with time clock and prese-
lection counter :
- wrong programming of time
clock or counter or no program-
ming at all.
Check programming.
b. Panel with computer :
- wrong programming of com-
puter or no programming at all.
Check instructions computer.
c. See 2-e.
YES
MAN
d. Operation button of circuit in
position ”0”.
This is no breakdown, but it prevents au-
tomatic operation.
e. Left
or
right
hand
motor
switched-off thermal-magnetic-
ally without being overloaded.
Check fuses. Check adjustment of motor
protection. Reload motor protection and
check its proper operation.
f. Left or right hand motor over-
loaded. (1 or more circuits).
1. Too much feed in the troughs. Have troughs emptied by the birds and
then adjust feeding programme.
2. Connector intake boot/trough
not properly tightened.
Firmly tighten the connector.
3. Auger coupling not properly
installed.
Check auger couplings and replace if
necessary
4. Auger kinked as a result of
careless installation.
Replace damaged auger.
5. Wheel inside intake boot is
blocked.
Disengage wheel or replace if neces-
sary.
6. Obstruction in the trough.
Find blocking spot and remove the ob-
struction. SEE NOTE .
YES
AUT.
g. Operation button of one or more
circuits in position ”0”.
This is no breakdown, but it prevents au-
tomatic operation. Put in position I.
h. See 5.e.
i. See 5. f.
j. See 2. e.
NOTE : IF THE AUGER OF THE CIRCUIT IS BLOCKED AS A RESULT OF ONE OF
THE ABOVE PROBLEMS, IT WILL BE UNDER SPRING TENSION, SO BE EXTREME-
LY CAREFUL AND PROCEED AS DESCRIBED IN THE NEXT PAGE*
DANGER
6. Circuit :
- stops pre-
maturely.
- does
not
stop
in
time.
YES
AUT.
a. Time set on time clock is not suf-
ficient.
Adjust time clock programming.
b. Timer not properly set (timer
0-999” inside control panel).
Adjust timer programming. (1 sec =
0,5m).
c. See 6.b.