BRIDOLAY-
USER'S GUIDE -
EU
ROXELL - 0715
6
TROUBLE SHOOTING GUIDE
Switch off the main switch first.
Use personal protective equipment.
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
FOR ANY AUTOMATIC OPERATION, NONE OF THE YELLOW LAMPS SHOULD BURN !
PROBLEM
LAMP
MAN/
AUT.
CAUSE
CORRECTIVE ACTION
1. No opera-
tion pos-
sible.
NO
MAN/
AUT.
No current.
Check main switch and/or fuses and/or
line current.
2. FA bin to
weigher
does not
run.
NO
MAN.
a. Operation button not on MAN
position.
Adjust button.
b. Remote control not properly
plugged.
Check plug.
NO
MAN./
AUT.
c. Max. switch of weigher remains
activated.
Check max. switch and repair or replace
it if necessary.
d. FA safety switch is activated.
Disengage safety switch and find cause
of blockage.
YES
AUT.
e. Reverse switch in position ”re-
verse” (inside the control panel).
This is no breakdown, but it prevents au-
tomatic operation. Put switch in position
”forward”.
YES
AUT.
f. FA operation button in position
”0” or ”II”.
This is no breakdown, but it prevents au-
tomatic operation. Put button in position
”I”.
YES
MAN.
g. Thermal-magnetic switch-off of
the FA.
Check fuses. Check adjustment of motor
protection. Reload motor protection and
check its proper operation.
YES
AUT.
h. See 2.g.
3. FA weigh-
er- to-cir-
cuits does
not run.
NO
MAN
a. See 2.a.
b. See 2.b.
c. Sensor remains activated. See
signal lamp sensor.
Check and repair.
NO
MAN/
AUT
d. See 2.c. and 2.d.
YES
MAN/
AUT
e. FA operation button in position
”0” or ”II”.
- See 2.e.
- See 2.g.
Put button in position ”I”.
4. FA weigh-
er-to-cir-
cuits short
cycles.
YES
MAN/
AUT
a. Sensor not properly installed.
See Installation instructions.
b. Timer of sensor adjusted too
low.
Adjust timer on a higher value.