![Roxell Boozzter User Manual Download Page 11](http://html.mh-extra.com/html/roxell/boozzter/boozzter_user-manual_1493840011.webp)
ROXELL - 0318
BOOZZTER
-
EU
9
TROUBLE SHOOTING GUIDE
Switch off the main switch first.
Use personal protective equipment.
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
FOR ANY AUTOMATIC OPERATION, NONE OF THE YELLOW LAMPS SHOULD BURN !
PROBLEM
YELLOW
LAMP
CAUSE
CORRECTIVE ACTION
1. None of the
feeder lines
run.
NO
No current.
Check main switch and/or fuses and/or line
current.
2. FA bin to
weigher
does not run
NO
a. Operation button not on ”ON” posi-
tion.
Adjust button.
NO
b. Max. switch of weigher remains
activated.
Check Max. switch and repair or replace it if
necessary.
c. FA safety switch is activated.
Disengage safety switch and find cause of
blockage.
YES
d. Thermal-magnetic switch-off of
the FA.
Check fuses. Check adjustment of motor
protection. Reload motor protection and
check its proper operation.
3. FA weigher
to
circuits
does
not
run.
NO
a. See 2.a.
b. Sensor remains activated. See
signal lamp sensor.
Check and repair.
NO
c. See 2.b. and 2.c.
YES
d. See 2.d.
4. FA weigher
to
circuits
short cycles
NO
a. Sensor not properly installed.
Check.
b. Timer of sensor adjusted too low. Adjust timer on a higher value.
5. The
circuit
does
not
run.
NO
Wrong programming of time clock or
counter or no programming at all.
Check programming.
YES
YES
a. Left or right hand motor of one or
more circuits switched-off without
being overloaded.
Check fuses. Check adjustment of motor
protection. Reload motor protection and
check its proper operation.
b. Left or right hand motor of one or
more circuits switched-off thermal-
magnetically (overloaded).
1. Too much feed in the tubes.
Have pans emptied by the birds. Check the
operation of the sensor in the control pan.
2. Connector intake boot/tube or
tube-elbow
not
properly
tightened.
Tighten connector correctly.
3. Auger coupling not properly in-
stalled.
Check auger couplings and replace if ne-
cessary.