14
2 • Plugging in the power cord
and using the vacuum cleaner
Unwind the power cord completely, plug in your
vacuum cleaner and press the ON/OFF button
(fig.10)
.
• Adjust the vacuuming power using the power
switch on the power nozzle
(fig.11)
:
• Position (MIN) for vacuuming delicate fabrics
(net curtains, textiles).
• Position (Medium) for every day vacuuming of
all types of floors, that are only slightly dirty.
• Position (MAX) for vacuuming hard floors and
rugs and carpets that are really dirty.
3 • Storage and transport of
the appliance
After use, switch off your vacuum cleaner by
pressing the ON/OFF button and unplug it
(fig.12)
. Rewind the power cord by pressing the
power cord rewind button
(fig.13)
.
Use the carrying power nozzle to carry your
vacuum cleaner easily
(fig.14)
.
When storing your vacuum cleaner, you can park
it either vertically or horizontally
(fig.16)
. Place
the tube in the storage slot underneath or at the
back of the appliance, in the parking position
(fig.17)
.
CLEANING AND MAINTENANCE
The air we breathe contains particles that may be
allergens: mite larvae and droppings, mould, pollen,
smoke and animal residues (hair, skin, saliva, urine).
The smallest particles penetrate deep into the
respiratory system where they can cause
inflammation and cause lung impairment.
HEPA filters (High Efficiency Particulate Air) are used
to filter out the smallest particles.
With the HEPA filter, the air released back into the
room is healthier than the air that is vacuumed.
1 • If you have the mechanical
model*: mechanical cleaning
of the HEPA filter
and emptying of the dust
container
Each time after use, we recommend that you
clean the HEPA filter to maintain optimum suction
power.
IMPORTANT
Do not use the power nozzle
of the dust container to carry the appliance
(fig.15)
.
*Depending on model:
this is either equipment specific to certain models or available as an optional accessory.
The HEPA filter is cleaned using the cleaning knob (6).
After use, switch off your vacuum cleaner, unplug it
and open the cover by pressing the "OPEN" button
(fig.18)
, remove the bowl
(fig.19)
, actuate the
HEPA filter cleaning knob by turning it in a
clockwise direction
(fig.20)
, then remove the
filter assembly (3 and 5)
(fig.22)
, tapping it
gently against the side of the bowl to remove any
excess dust
(fig.23)
then empty the dust
container
(fig.24)
. Clean the separator the cover
using a cloth if it is dirty
(fig.25)
. Put the filter
assembly (3 and 5) back inside the dust container
(fig.26)
. Then fit the dust container back into its
housing and close the vacuum cleaner cover
(fig.27)
.
IMPORTANT
Do not use the vacuum cleaner
once the maximum level is reached I the dust
container.
IMPORTANT
Do not operate your vacuum
cleaner without the filtration system fitted (3 and 5).
IMPORTANT
Always switch off and unplug
your vacuum cleaner before cleaning or
servicing.
IMPORTANT
Each time after use, we
recommend that you turn the HEPA filter
cleaning knob 6 times completely, so that your
vacuum cleaner maintains full suction power.
EN
751271_SF Cyclonic_16L_751271 08/12/10 11:23 Page14
Summary of Contents for CYCLONIC
Page 58: ...59 2002 95 CE i Rowenta e e e RU 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page59...
Page 71: ...72 TR 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page72...
Page 96: ...97 AR 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page97...
Page 97: ...27 23 98 AR 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page98...
Page 100: ...101 AR 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page101...
Page 101: ...102 AR 751271_SF Cyclonic_16L_751271 08 12 10 11 24 Page102...