background image

 

S2

USER MANUAL

 

 

 

 

 

S2 

SCOUT

 

 
 
 

USER MANUAL  

 
 

 
 

Analogue and Digital Satellite Analyzer  

930 - 2150 MHz QPSK 

 
 
 
 
 

 

 
 

 

 

ROVER LABORATORIES S.p.A. 

Via Parini 2 – 25019 Sirmione (BS) – ITALY 

www.roverinstruments.com 

 

Summary of Contents for S2 SCOUT

Page 1: ...S2 USER MANUAL S2 SCOUT USER MANUAL Analogue and Digital Satellite Analyzer 930 2150 MHz QPSK ROVER LABORATORIES S p A Via Parini 2 25019 Sirmione BS ITALY www roverinstruments com...

Page 2: ...re targeted to continuously develop state of the art instruments capable to fulfil and possibly to exceed your expectations and all of your needs We are able to research and develop further improvemen...

Page 3: ...R MULTISWITCH SUPPORTING THE SCR COMMUNICATION PROTOCOL SAT SCR MENU 10 SatSCR USER 10 SatSCR FREQ 10 7 __ DC AT RF IN 11 8 __ SATELLITE DISH ALIGNMENT 12 8 1 DISH ALIGNMENT TO A SPECIFIC SATELLITE WI...

Page 4: ...LIST OF THE CURRENT BOUQUET 26 SPECTRUM ANALYSIS 26 11 _ SPECTRUM ANALYZER MODE 27 11 1 CHANGE THE TRANSPONDER 27 11 2 CHANGE THE MARKER POSITION FREQUENCY 27 11 3 EDITING THE SIGNAL LEVEL END OF SCAL...

Page 5: ...H Power Meas press 2 RESET press and hold 10 B MPEG SERVICE LIST Enable configuration menu C LCD Dot matrix Display D PLAN AUTOSCAN E SAT FINDER DUAL LNB F SPECT SAT POINT G MEAS H UP also Enter key I...

Page 6: ...S2 USER MANUAL 6 2 SIDE PANELS S External Power Source 12 Vac T USB socket U RF inlet 75 type F connector...

Page 7: ...play B an icon will show the current power source of the meter built in battery or mains external feed Build in battery feed Mains external feed Connect the supplied AC adaptor or the supplied cigaret...

Page 8: ...cally turn off after a certain time delay To set the auto meter off delay Press repeatedly the SELECT M key to highlight the label TIMER OFF Press repeatedly either the UP H or the DOWN L key to selec...

Page 9: ...e UP H or the DOWN L key to select FullON light always on or 30 sec light off after 30 sec 6 2 METER SETUP Press repeatedly the SELECT M key to highlight the label SAT CONFIG SCR Press the UP H key to...

Page 10: ...y to highlight the label SatSCR USER Press repeatedly the UP H o DOWN L to set the user identification number The measurement in progress will be referred to this user It is possible to identify up to...

Page 11: ...n I will turn on too WARNING BEFORE TURNING THE DC AT RF IN FUNCTION ON PLEASE CAREFULLY CHECK WHETER THE SYSTEM WHICH THE METER IS CONNECTED TO IS SUITABLE FOR THE DC AT RF IN To turn the DC at RF in...

Page 12: ...efer to chapter 9 SIGNAL TUNING PLAN at page 17 and in detail to item9 3 NAVIGATE THE SOLE TRASPONDERS INCLUDED IN A USER DEFINED MEMORY PLAN at page 20 Press the SAT FINDER E key to show the followin...

Page 13: ...Using the UP H and DOWN L keys select a transponder with a different polarization B polarization and just repeat the dish fine alignment on this last transponder To confirm the alignment just check t...

Page 14: ...the LNB1 will be highlighted DISH ALIGNMENT AND FINE ALIGNMENT When LNB1 and LNB2 have been selected the display shows for each LNB the Noise Margin and Quality Test FAIL MARGIN PASS The two level bar...

Page 15: ...highlighted this item indicates the command which will be sent to the motorized antenna By pressing the UP H or DOWN L key it is possible to select one of the 4 available commands MOVE This command mo...

Page 16: ...TING AID TONE BUZZER Press and hold for 2 the HELP P key You can hear a beep whose duty cycle is proportional to the signal Noise Margin This is a dish alignment aid feature when the multiplex DVB is...

Page 17: ...atellite should be highlighted If not select the required satellite by pressing repeatedly either the UP H or DOWN L key Press the MEAS G key The first row of the display will show the name of the sel...

Page 18: ...ency just keep pressed either the UP H or DOWN L key up to reach the desired frequency 9 2 MANUALLY TUNING THE TRANSPONDER BY KNOWING ALL THE DISTINCTIVE PARAMETERS IT IS MANDATORY TO KNOW ALL THE DIS...

Page 19: ...DOWN L key To quickly change the frequency just keep pressed either the UP H or DOWN L key up to reach the desired frequency Press once the SELECT M key to highlight S R Symbol Rate and then set the r...

Page 20: ...n Press the MEAS G key The display first row will show the selected transponder memory plan MANU the current transponder identification number and its frequency SELECT THE DESIRED TRANSPONDER Highligh...

Page 21: ...e frequency just keep pressed either the UP H or DOWN L key up to reach the desired frequency MODIFY THE TRANSPONDER MEMORY PLAN TO BE NAVIGATED The Transponder Memory Plan can be changed only from th...

Page 22: ...atus third row on the right Local oscillator frequency fourth row on the left On the right bottom angle the letter S will appear matching the SAT label on the meter also a black square will appear mat...

Page 23: ...s and only if the quality of the signal is sufficient orbital position of the received satellite encrypt used by the network if at least one program of the network is encrypted will appear after a few...

Page 24: ...er and a open lock will match the DIG label WHILE SHOWING THIS SCREEN THE LOCK WILL ALWAYS APPEAR OPEN EVEN IF THE SIGNAL IS CORRECTLY LOCKED CHANNEL POWER MEASUREMENT The bottom part of the above scr...

Page 25: ...SAT label on the meter a lock matching the DIG label on the meter it will appear closed if the signal has been correctly locked if not it will appear open BER MEASUREMENTS BEFORE AND AFTER VITERBI COR...

Page 26: ...er screen might be accessed directly from any screen by pressing once the ON A key SERVICE LIST OF THE CURRENT BOUQUET Press the MPEG PROG SERVICE B to show the list of the programs included in the bo...

Page 27: ...to chapter 9 SIGNAL TUNING PLAN at page 17 11 2 CHANGE THE MARKER POSITION FREQUENCY Press the SELECT M key to highlight the frequency area and modify the marker position by pressing either the UP H o...

Page 28: ...SPAN Press the SELECT M key to highlight the actual span value SP The value can be changed by pressing either the UP H or the DOWN L key Only pre defined values from 50 MHz to FULL can be set 11 5 AC...

Page 29: ...STORE TRANSPONDER MEASURES AUTO MEAS STORE Press and release the DATA LOGGER Q key to access the following screen In the second row from the top PLAN the display shows the channel plan which channels...

Page 30: ...he former data will be deleted without further notice To start the auto Meas Store press the SELECT M key repeatedly to highlight the item SAVE or resp OVERWRITE e press the UP H key In the lowest par...

Page 31: ...either the UP H or the DOWN L key to select the first available free memory plan Press repeatedly the SELECT M key to highlight in the display second row the kind of signal to be stored analogue digi...

Page 32: ...stored in the display second row analogue digital DVB S digital DSS and select the desired signal by pressing either the UP H or the DOWN L key Press repeatedly the SELECT M key to highlight the high...

Page 33: ...ss the SELECT M key to highlight SELECT TYPE Press either the UP H or the DOWN L key to select PLAN Press the SELECT M key to highlight SELECT FILE Press either the UP H or the DOWN L key to select th...

Page 34: ...either the UP H or the DOWN L key to select LOGGER Press the SELECT M key to highlight SELECT FILE Press either the UP H or the DOWN L key to select the name of the Memory Plan to be deleted LOG 01 L...

Page 35: ...on Encryption status detection Encryption status indicator Bouquet service list with audio and video PID table Special function SAT Exploring satellites Exploring transponder SAT LNB S C R driver DiSE...

Page 36: ...cable ROVER s everyday efforts constantly aim at developing better and better instruments more reliable and easier to use Thus we know you will be on our side when we update the core software powering...

Page 37: ...environments 4 The following parts are not covered by the guarantee a Parts subject to wear such as aesthetic ones keyboard plastic chassis b Batteries c Bags and carrying cases included shoulder str...

Page 38: ...ument is not under guarantee after repair the equipment will be returned by courier service with the amount to be paid by the customer shown in the invoice 8 The guarantee does not cover compensation...

Page 39: ...e key please specify is not working ENCODER IF AVAILABLE does not work if pressed does not work if turned DISPLAYS on LCD display pictures and or labels are either totally lacking or incomplete on TFT...

Page 40: ...y rapidly loose its efficiency if exposed to high or low temperatures This will result in reduced autonomy of the meter when powered by internal battery When recharging the internal battery do allow a...

Page 41: ...the moment of disposal should be brought to a waste collection point with the proper facilities to manage electrical electronic appliances Electric electronical appliances if not disposed of correctly...

Page 42: ...S2 USER MANUAL 42 NOTE...

Page 43: ...S2 USER MANUAL 43 NOTE...

Page 44: ...44 Caring about you ROVER LABORATORIES S p A Via Parini 2 25019 Sirmione BS ITALY Tel 39 030 91981 Fax 39 030 9906894 wecare roverinstruments com www roverinstruments com...

Reviews: